Online training course to build a medical device quality management system that meets regulatory requirements and is ready for certification.
This practitioner training course covers implementing ISO 13485:2016: for every clause, what it asks for, how to put it in place for your own devices and regulatory requirements, what documented procedures and records it needs and how to check that it works. A maker of sterile infusion sets in Singapore runs through the course.
What you get
About 6 hours, with captions. Watch at your own pace on any device.
Short questions check your understanding before you move on.
Score at least 60% to receive the Certificate of Competence.
Industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC.

Verifiable certificate with a QR code anyone can scan, plus a digital badge to add to your LinkedIn profile.
See how verification works →Standard and editionISO 13485:2016
Last updated27 October 2026
Preview this course
Watch a sample from ISO 13485:2016 Implementation Training before you enrol.
Learning outcomes
Connect the subject to the responsibilities and decisions people encounter in their roles.
Part of: Medical Device Quality and Risk Management Training
Part of: GMP & Medical Devices
Inside the course
26 modules, 26 practice checkpoints, 7 practice exercises and a final exam. Video runtimes are approximate; allow additional time for the practice questions and the final exam. Modules marked optional can be skipped; the others are studied in any order.
Introduces ISO 13485:2016 and why device makers need a quality management system, in a training course following XYZ Ltd., a Singapore infusion set maker.
Opens with the question of how you know every device you shipped was made under control. Sets out the course: twenty-six modules in three parts, the seven steps used for each requirement, practice, written exercises and a final exam. Then covers the standard's purpose for regulatory purposes, who can use it, how it relates to the general quality standard, the 2016 edition with five changes, and what a working system gives a device business.
What you will be able to do
Why it matters
When a hospital asks how you know every device was made under control, a working system lets you answer with records, not promises.
Practice: Practice: Welcome: a QMS for medical devices · 3 questions
Explains the defined terms and key phrases of ISO 13485:2016, such as complaint, risk, as appropriate, shall and supply chain roles, and why they matter.
Starts with a nurse's phone call about a roller clamp, logged as a service request in one version and as a complaint in the other. Covers clause 2 and clause 3, the phrases as appropriate and documented, and the words shall, should, may and can. Then defines medical device, life-cycle, device family, manufacturer, importer, distributor, authorised representative, risk, complaint and labelling, with examples from XYZ Ltd. in Singapore and a warehouse in Sydney.
What you will be able to do
Why it matters
Reading the standard with everyday meanings leads to missed complaints and the wrong role, so one definition can decide what you must do.
Practice: Practice: The language of the standard · 3 questions
Shows how ISO 13485:2016 is built, the process approach, the roles you hold, what may be left out and how to run a gap assessment before writing documents.
Begins with the choice between renaming an old quality manual and first comparing current practice with every requirement. Covers the eight clauses and two annexes, the process approach, and how the roles of XYZ Ltd. in Singapore, an importer in Toronto and a contract moulder change the system. Explains exclusion of design controls and non-application, then the five-step gap assessment with example findings and a draft scope.
What you will be able to do
Why it matters
Companies that find out where they stand first close the gaps that put devices at risk first, and this training course then builds only the documents needed.
Practice: Practice: How the standard is built · 3 questions
Covers general requirements of a medical device quality system: documented roles, risk-based process control, change, outsourcing and software validation.
Begins with a contract steriliser that changes how it loads its chamber without telling XYZ Ltd. Walks through the six parts of clause 4.1: the system and your roles, processes and the risk based approach, what each process needs, changes, outsourcing and software. Examples include a process card for bonding, a written quality agreement, a pump servicer in London and validation of a complaint database.
What you will be able to do
Why it matters
Outsourcing a process never outsources the responsibility, so control that follows the risk to the device lets you know about a supplier's change in time.
Practice: Practice: General requirements · 3 questions
Covers the documentation a medical device quality system must include, the quality manual and the medical device file kept for each device type or family.
Begins with an importer in Dubai asking for the documents that define XYZ Ltd.'s infusion sets. Covers what clause 4.2.1 lists, the layers of documents, the contents of the quality manual in clause 4.2.2, and the medical device file in clause 4.2.3 with its six kinds of content. Uses a file index, one-file-or-two for a tubing family, and a hospital bed maker in Toronto.
What you will be able to do
Why it matters
If you cannot show how a device is defined and made, you cannot show it is under control, and a registration can be delayed by one old label.
Practice: Practice: The quality manual and the medical device file · 3 questions
Explains document control and record control in a medical device quality system, including the eight document controls and how long records are kept.
Starts with an old printout left at one packing station of XYZ Ltd. Separates documents from records, then goes through the eight controls of clause 4.2.4, the five stages from create to withdraw, and a master list. For clause 4.2.5 it covers the six record controls, confidential health information, visible corrections, and the retention rule of the device lifetime and never less than two years.
What you will be able to do
Why it matters
One old instruction can make a whole batch wrongly, and one missing record leaves a batch you cannot defend, so control keeps both under check.
Practice: Practice: Control of documents and of records · 3 questions
Covers what top management must do under ISO 13485:2016: commitment, customer focus, the quality policy, measurable quality objectives and system planning.
Opens with a quality objective that rewards shipping more infusion sets, and what it did to leak checks at XYZ Ltd. in Singapore. Covers the five ways top management shows commitment, customer focus, the five points a quality policy must meet and the word understood. Then looks at measurable objectives by function, a distributor in Dubai, a servicing company in London, and planning for changes such as a new ERP.
What you will be able to do
Why it matters
Objectives decide where people put their effort, so a sales target posted as a quality objective can let complaints rise while the numbers look good.
Practice: Practice: Commitment, policy and objectives · 3 questions
Explains responsibility and authority, the management representative and internal communication, so people know who may stop a shipment before it matters.
Opens with a night shift in sterile packing at XYZ Ltd. where a weak pouch seal is found and nobody is sure who may hold the batch. Covers clause 5.5.1 on defined authority, interrelation and independence, then the management representative of clause 5.5.2 with its three duties, examples from Toronto and Manila, and clause 5.5.3 on internal communication, including what the channels must carry.
What you will be able to do
Why it matters
Authority that is clear before it is needed lets a supervisor hold a doubtful batch at night, and problems reach people who can pay to fix them.
Practice: Practice: Roles, representative and communication · 3 questions
Explains how to run a management review of a medical device quality system, with its twelve required inputs, recorded outputs and decisions with owners.
Begins with a six-monthly review at XYZ Ltd. in Singapore where rising clamp complaints were shown and nothing was decided. Covers the documented procedure and planned intervals of clause 5.6.1, the meaning of suitable, adequate and effective, and the twelve inputs of clause 5.6.2 grouped as field, checks, actions and change. Then the four groups of output in clause 5.6.3, with a review cycle and examples from Hong Kong and Sydney.
What you will be able to do
Why it matters
A review is measured by its decisions, and minutes that say discussed leave a rising complaint trend with nobody responsible for it.
Practice: Practice: Management review: input and output · 3 questions
Covers providing resources and human resources: determining competence, closing gaps, checking training effectiveness in proportion to risk, and awareness.
Opens with a new cleanroom operator at XYZ Ltd. in Singapore who signs an attendance sheet and starts work alone. Covers clause 6.1 on determining then providing resources, and clause 6.2 on competence for anyone whose work affects product quality, including agency staff and night cleaners. Follows the cycle of determine, compare, act, evaluate and record, with a sterile packing operator profile, and examples from New York and Mumbai.
What you will be able to do
Why it matters
Attendance shows a person was in the room, while records of a checked competence show she can do the job, which protects the device.
Practice: Practice: Resources and human resources · 3 questions
Covers infrastructure and its maintenance, the controlled work environment and contamination control for medical devices, including sterile devices.
Opens with a cleanroom pressure monitor at XYZ Ltd. in Singapore that stopped recording for ten days while nine batches were packed. Covers clause 6.3 on documented infrastructure, preventing mix-up and maintenance with intervals, then clause 6.4.1 on the work environment, rules for health, cleanliness and clothing, clause 6.4.2 on contaminated product, and sterile devices. Examples include a distributor in Manila and a pump servicer in London.
What you will be able to do
Why it matters
A device is made right only under conditions you can show, so a monitor that stops recording unnoticed can leave you with no evidence for nine batches.
Practice: Practice: Infrastructure and work environment · 3 questions
Covers planning of product realization and the documented risk management process that links design, purchasing, production and feedback for a medical device.
Begins with XYZ Ltd. launching an infusion set with a finer flow clamp when the only plan is a launch date. Covers the four points of clause 7.1, what planning must determine, and as appropriate. Then risk as defined in clause 3, the outline of ISO 14971, the thread of risk through the standard, a sealer risk record, and when to revisit the plan, with a pump servicer in Sydney.
What you will be able to do
Why it matters
A risk file can be excellent and still fail the patient if purchasing and production never read it, so the plan carries the risks into every process.
Practice: Practice: Planning realization and risk management · 3 questions
Explains how to determine and review customer requirements before accepting a medical device tender or order, and how to plan communication with customers.
Begins with XYZ Ltd. in Singapore bidding on a hospital tender for sets not yet registered in that country. Covers the five sources of requirements in clause 7.2.1, including user training, and the review before commitment in clause 7.2.2 with its records and confirmation of phone orders. Then clause 7.2.3 on planned communication about product information, orders, feedback and advisory notices, with examples from Dubai, Toronto and Hong Kong.
What you will be able to do
Why it matters
Saying yes only to what you can deliver protects both the order and the distributor, because a review done after acceptance cannot change the answer.
Practice: Practice: Customer-related processes · 3 questions
Covers design and development controls for medical devices: the procedure, planning, verifiable inputs, outputs and design reviews, and who may exclude them.
Opens with a hospital bed maker in Toronto whose side rail fails with gloved nurses. Covers clause 7.3.1, who needs design controls and when they are not applicable, and outsourced design under a quality agreement. Then planning with six documented items and a traceability matrix, inputs in clause 7.3.3 including risk management outputs, outputs in clause 7.3.4, and design review records in clause 7.3.5, using XYZ Ltd. in Singapore.
What you will be able to do
Why it matters
A design error reaches every device you make and costs the most to fix after release, so inputs and reviews catch it while it is cheap.
Practice: Practice: Design and development: plan, inputs, review · 3 questions
Covers design verification and validation, design transfer to manufacturing, control of design changes and the design and development file for a medical device.
Opens with a patient monitor maker in New York whose slimmer battery fails on the charging dock. Separates verification, did we build it right, from validation, did we build the right thing, then covers clause 7.3.6 to clause 7.3.10: connected devices, clinical and performance evaluation, validation on initial production units, transfer, significance of changes, and the design file. Examples from XYZ Ltd., Sydney and Manila.
What you will be able to do
Why it matters
A design can meet every verification and still fail validation, and no change is too small to review before it reaches the market.
Practice: Practice: Design and development: verify to files · 3 questions
Explains purchasing for medical device makers: choosing suppliers by risk, monitoring them, sending purchasing information and verifying what arrives.
Begins with a blood collection tube maker in Mumbai whose supplier quietly switched to a cheaper rubber. Covers purchased product, supplier criteria proportionate to risk in clause 7.4.1, monitoring and re-evaluation, outsourced processes under written quality agreements, and purchasing information in clause 7.4.2 with a change notification clause. Then verification in clause 7.4.3, with a resin purchase order from XYZ Ltd. and examples from Dubai and Toronto.
What you will be able to do
Why it matters
Much of every device is bought in, and a certificate on file is a start, not a control: hear about a change before your device does.
Practice: Practice: Purchasing: suppliers and checks · 3 questions
Explains controlling production and service provision for medical devices: batch records, cleanliness, installation, servicing and records for sterile devices.
Begins with a catheter maker in Sydney whose two sizes ran on one line without clearing it. Covers the six controls and the record for each batch under clause 7.5.1, cleanliness of product in clause 7.5.2, installation in clause 7.5.3, servicing records treated as possible complaints in clause 7.5.4, and sterile device records in clause 7.5.5. Uses XYZ Ltd.'s cleanroom line, a distributor in Hong Kong and a bed installer in Dubai.
What you will be able to do
Why it matters
Control the process, not just the product: a record made at the step, by the person doing the work, gives every unit a story you can tell.
Practice: Practice: Production control and sterile devices · 3 questions
Explains process validation for production and service, including software, sterilisation and sterile barrier systems, and when a process must be revalidated.
Opens with a contract manufacturer in Toronto that replaced a worn ultrasonic welder and restarted with the same settings. Covers which processes need validation under clause 7.5.6, with four XYZ Ltd. processes sorted, the contents of a validation procedure, sample size rationale, revalidation criteria and software. Then clause 7.5.7 on sterilisation and the sterile barrier system, including an outsourced steriliser, a moulder in Mumbai and a London service company.
What you will be able to do
Why it matters
When nobody can see a defect until the device is in use, proven and recorded process limits are the only control, and they must stay current.
Practice: Practice: Process validation and sterilisation · 3 questions
Covers identification and product status, traceability to the extent regulations require, customer property and preservation of product for medical devices.
Opens with an orthopaedic screw maker in London that can trace a cracked screw to one material lot. Covers clause 7.5.8 on identification, status labels, unique device identification and returned devices, clause 7.5.9 on traceability, including implantable devices and distributor records, clause 7.5.10 on customer property, and clause 7.5.11 on preservation. XYZ Ltd. shows its trace chain, with a distributor in Hong Kong.
What you will be able to do
Why it matters
Traceability decides how many devices you look for when one fails, so testing the chain before a recall does keeps the search short.
Practice: Practice: Identification and traceability · 3 questions
Explains control of monitoring and measuring equipment: choosing instruments, calibration to traceable standards and what to do when a gauge is found wrong.
Begins with a syringe maker in Manila whose force gauge was found reading wrongly with no record of which batches it tested. Covers clause 7.6: starting from the measurement the product needs, the five controls of calibration, adjustment, identification, safeguarding and protection, and the look-back at earlier results when equipment is out of tolerance. Also software that measures, with XYZ Ltd.'s pull tester and examples from New York and Toronto.
What you will be able to do
Why it matters
A result is only as good as the instrument behind it, and naming the instrument on each record keeps a faulty gauge from holding up every batch.
Practice: Practice: Monitoring and measuring equipment · 3 questions
Covers how clause 8 begins, then feedback, complaint handling and reporting to regulatory authorities, including what counts as a complaint.
Opens with three calls about a cracked drip chamber to an importer in Dubai, handled as returns in one version and as complaints in the other. Covers the planning of measurement and analysis in clause 8.1, feedback in clause 8.2.1 and post-market surveillance, the definition of a complaint, the six points of clause 8.2.2, and reporting to regulators in clause 8.2.3 with advisory notices. Includes XYZ Ltd.'s complaint record.
What you will be able to do
Why it matters
Every complaint is a signal, and a recorded decision with its reasons lets you explain yourself when a regulator asks.
Practice: Practice: Feedback, complaints and reporting · 3 questions
Explains how to plan internal audits, monitor processes and check product before release, so a medical device system is tested before a complaint tests it.
Begins with a Friday batch from the contract steriliser at XYZ Ltd. whose records arrive on Monday. Covers internal audit in clause 8.2.4: the documented procedure, a programme set by risk and past results, objective auditors who never audit their own work, and verified follow-up. Then monitoring of processes in clause 8.2.5 with example measures, and product monitoring in clause 8.2.6, including release records and implantable devices.
What you will be able to do
Why it matters
Auditing where the risk is and verifying every action before closing it shows the system works before a complaint says it does not.
Practice: Practice: Internal audit and monitoring · 3 questions
Covers controlling nonconforming product before and after delivery, concessions, advisory notices, rework and the analysis of data under ISO 13485:2016.
Begins with a Friday lot of connectors out of tolerance at XYZ Ltd. in Singapore and a supervisor who uses them anyway. Covers the documented procedure of clause 8.3.1, the three ways to act before delivery with concession rules in clause 8.3.2, action after delivery and advisory notices ready at any time in clause 8.3.3, rework in clause 8.3.4, and analysis of data in clause 8.4, with a quarterly data review.
What you will be able to do
Why it matters
Product that does not conform is identified, held and decided on, never left to chance, so anyone can later see who decided and why.
Practice: Practice: Nonconforming product and data · 3 questions
Explains improvement through corrective and preventive action: finding true causes, checking for adverse effects and reviewing effectiveness.
Opens with leaking connectors at XYZ Ltd. that return three times because retraining the operator never reached the cause. Covers improvement in clause 8.5.1, the difference between correction, corrective action and preventive action, and the six points of clause 8.5.2, with proportionate effort, the check that an action does no harm and asking why with facts. Then preventive action in clause 8.5.3 using drifting seal results and a battery trend in New York.
What you will be able to do
Why it matters
Remove the cause and the problem stops coming back, which costs less than repeated replacements and the hard questions an importer will ask.
Practice: Practice: Corrective and preventive action · 3 questions
Maps the documented procedures and records ISO 13485:2016 requires, what regulations may add and what is your choice, so you write only what is missing.
Starts with a brand owner in London auditing XYZ Ltd. and asking for procedures that were never written. Shows how to read document, maintain records and as appropriate under clause 0.2, then walks through the standard in order: policy and manual, the procedures of clause 4 to clause 8, and the records that follow the product and show the system works. Covers retention, what regulations add such as unique device identification, and the records matrix.
What you will be able to do
Why it matters
A copied set of procedures leaves gaps exactly where medical devices differ, while the map taught in this training course answers an auditor in minutes.
Practice: Practice: The procedures and records you need · 3 questions
Sets out a dated road map to ISO 13485:2016 certification: owners, gap assessment, build and run phases, readiness checks and the two-stage certification audit.
Opens with XYZ Ltd. needing certification for a tender, and two versions of how it prepares. Covers starting with top management, roles, markets, scope and gaps, then building and running the system so records exist. Lists the items that take longest, six readiness checks, four questions for choosing a certification body, the two audit stages and the surveillance cycle, regulators, and what comes next in this training course.
What you will be able to do
Why it matters
Certification follows a system that already runs, so starting the long items early lets records build up before the auditor asks for them.
Practice: Practice: Your road map and certification readiness · 3 questions
Frequently asked questions
About ISO 13485:2016 Implementation Training, its certificate and enrolment.
Ask SterlingYes. Sterling Academy's ISO 13485 courses are built by the Sterling consulting group, which has taken organisations to certification across 8,100+ client engagements in 60+ countries over 20+ years. They cover the awareness, implementation, internal auditor and specialist levels, always on the current edition, with practice questions that show the right answer. Each course ends with a final exam and a verifiable certificate that anyone can check online, plus a LinkedIn badge, and client administrators can show an auditor exactly who has been trained. You will be able to implement the ISO 13485 management system and face the certification audit with confidence. Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.
Awareness: ISO 13485 Awareness · Implementation: ISO 13485:2016 Implementation Training · Internal auditor: ISO 13485:2016 Internal Auditor Training · Specialist: ISO 14971 Medical Device Risk Management
It is for QMS leads building or rebuilding an ISO 13485 system, regulatory affairs specialists, design, production and supply-chain leads, and managers of medical device companies and contract manufacturers. It suits organisations preparing for their first certification or accreditation and those rebuilding an existing system. Learners new to ISO 13485 may start with Sterling Academy's ISO 13485 awareness course.
It covers how to put a medical device quality management system in place, clause by clause: ISO 13485:2016, the language of the standard, and the roles an organisation takes; general requirements, the quality manual, the medical device file, and control of documents and records; management responsibility, the management representative and management review; resources, competence, infrastructure, work environment and contamination control; product realization: planning and risk management, customer processes, design and development, purchasing; production: cleanliness, sterile devices, process and sterilization validation, traceability and monitoring equipment; measurement and improvement: feedback, complaints, regulatory reporting, audits, nonconforming product and CAPA; the documented procedures and records you need, and your road map to certification.
The course has 26 video modules and about 6 hours of video, with practice exercises after key modules and a final exam. Video runtimes are approximate, so allow additional time for the exercises and the exam. With 12 months of access, you can complete it in one sitting or spread it over several sessions.
Yes. Learners who score at least 60% in the final exam receive a Sterling Academy Certificate of Competence for ISO 13485:2016 Implementation Training. The written exercises are practice with feedback and do not count toward the result. A learner who does not reach the pass mark has one retake, which opens 24 hours after the result; a learner who finishes the course but does not reach it on the retake receives a Certificate of Completion. Each certificate carries a unique number and a QR code, and anyone can check it online.
Yes. ISO 13485:2016 Implementation Training is a self-paced online course made of short video modules, in English with captions. You study at your own pace during 12 months of access, and practice exercises with feedback help you apply each requirement to your own organisation. If a point is unclear, questions are answered by a Sterling consultant.
ISO 13485:2016 Implementation Training has a list price of US$149 per learner, with a limited-time offer of US$99 per learner until 31 December 2026. Teams save 20% for 11 to 50 learners and 30% for 51 to 200; 201 or more learners are priced on request. Client administrators can track their team's progress. Prices are in US dollars, excluding taxes, and Sterling confirms final pricing and enrolment.
It gives your people the knowledge ISO 13485 asks of them, and each learner's verifiable certificate is evidence of that training when the auditor asks. The course gives you the knowledge to implement ISO 13485 in your organisation; the certificate is a training certificate for the individual learner. Sterling's expert and experienced consultants can support your implementation from gap assessment to readiness.
Learning path
Start here
Build awareness of quality management for medical devices and the role of controlled processes, documentation and individual responsibilities.
View courseThis course
Put every ISO 13485:2016 requirement in place for your own devices and regulatory requirements, from the medical device file and design controls to sterile production, complaints and certification readiness.
Your certificate
You will be able to implement the ISO 13485 management system and face the certification audit with confidence. Your certificate can be verified online in seconds, so certification body auditors, employers and clients can confirm your training instantly.
Reach the pass mark in the final exam and you receive a Sterling Academy Certificate of Competence, verifiable online by QR code, with a LinkedIn badge to share. Employers, clients and auditors can check it in seconds. Every learner who finishes the course receives a certificate: a Certificate of Completion when the retake does not reach the pass mark.
Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.