Ready to put ISO 14971 Medical Device Risk Management into practice?
Expert and experienced consultants, 8,100+ client engagements in 60+ countries, from gap assessment to a system ready for its certification audit.
Talk to a Sterling consultantPractitioner training · Medical device quality
Online training to build and keep alive a risk management file that stands up to scrutiny.
Built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC. 8,100+ client engagements in 60+ countries.
What you will be able to do
ISO 14971:2019 Medical Device Risk Management is a practitioner course for risk, design, software, quality and regulatory teams. Learners will build and maintain a risk management file, apply risk controls in the right order and act on residual risk and post-production data. Study is online and self-paced, and a final exam leads to a verifiable certificate.
The training is a practitioner course on ISO 14971:2019, Medical devices — Application of risk management to medical devices: the policy and plan, risk analysis, evaluation and control, overall residual risk, the risk management review, and production and post-production information, with the links to ISO 13485:2016.
Part of: Medical Device Quality and Risk Management Training
Part of: GMP & Medical Devices
How the course works
Every Sterling Academy course takes you through the same stages, so you leave with a skill, not just a summary.
What you get
About 4 hours, with captions. Watch at your own pace on any device.
Short questions check your understanding before you move on.
Multiple choice; retakes are unlimited and included in the price.
Industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC.
Preview this course
Watch a sample from ISO 14971:2019 Medical Device Risk Management before you enrol.
Inside the course
33 modules, 33 practice checkpoints and a final exam. Video runtimes are approximate; allow additional time for the practice questions and the final exam.
Shows why patients rely on the maker's risk decisions and introduces the five-move process that ISO 14971 gives a manufacturer.
Opens with a hospital buyer asking who decided that an infusion pump was safe enough, and what happens to a maker with no clear answer. Compares everyday risk with the position of a patient who cannot see inside a device. Introduces the five moves of ISO 14971: identify, estimate, evaluate, control and monitor, across the whole life of the device, and the four example devices followed through the course of 33 modules.
What you will be able to do
Why it matters
Gives managers and quality leads a clear answer to a buyer's first question: who decided this device was safe enough, and how?
Practice: Practice: Why device risk management matters · 3 questions
Sets out which devices, life-cycle phases and people ISO 14971 covers, and when a distributor or importer takes on a manufacturer's duties.
Covers what ISO 14971 applies to: medical devices, software and in vitro diagnostics, and risks from biocompatibility to usability. Follows the device from the first idea to disposal, with post-production still the maker's responsibility. Explains who counts as the manufacturer, using a relabelled batch of self-tests in Dubai and a contract steriliser in Manila. Names what is outside the standard, such as organisational risk in general, which points to ISO 31000, and why a quality management system, such as one to ISO 13485, is not required.
What you will be able to do
Why it matters
Helps distributors, importers and makers see when a label change brings manufacturer duties, before a shipment goes out.
Practice: Practice: Scope, life cycle and the manufacturer · 3 questions
Shows where ISO 13485 requires risk management and how ISO 14971 supplies the process, through design, purchasing, complaints and software.
Explains that ISO 13485 requires documented risk management processes and records in product realisation, and ISO 14971 shows how to do it. Clarifies that risk in ISO 13485 means risk to safety, performance or regulatory requirements, not commercial risk. Traces the thread through design, suppliers, training, software validation and corrective action, and separates product risk from process risk, using a safety scalpel maker in Penang whose purchasing procedure ignored its main hazard.
What you will be able to do
Why it matters
Helps you find risk gaps in purchasing, complaints and other procedures before an audit does.
Practice: Practice: ISO 14971 and ISO 13485: one thread · 3 questions
Defines hazard, hazardous situation and harm, and shows how to write a register row that names the thing, the moment and the injury.
Starts with a pan of hot oil at home to separate the three words at the heart of ISO 14971. Defines a hazard as a potential source of harm, a hazardous situation as exposure to it, and harm as injury or damage to health, property or the environment. Applies the chain to the scalpel, infusion pump, dose app and self-test, including a wrong number as a hazard, and rewrites a weak electric shock row into one that can be scored.
What you will be able to do
Why it matters
Prevents registers that auditors cannot follow, and the missed hazards that come from mixing up these three words.
Practice: Practice: Hazard, hazardous situation, harm · 3 questions
Shows how a hazard reaches a person through a sequence of events, and why breaking the chain early and automatically works better.
Builds on the three words with a night-shift example: an infusion pump cassette lifted out before the line is clamped, drawn as a chain of events. Shows that one hazard can lead to several situations and each situation to several harms, with sequences starting at any life-cycle phase. Compares early, automatic breaks with late, human ones, using a self-test read too late and a worn strap in a logistics firm in Lagos.
What you will be able to do
Why it matters
Earlier breaks in the chain give stronger and cheaper controls than a warning added at the end.
Practice: Practice: Sequences of events · 3 questions
Explains risk as the combination of severity and probability of harm, and how to score each with a stated reason and source.
Uses a road-trip example, a likely flat tyre against a rare brake failure, to show the two parts of risk. Covers scoring the worst credible harm for severity, thinking of probability in two steps, and writing the reason and source next to every number. Warns against scoring every severity at the top. Examples include a false positive and a false negative on the self-test, and a nuisance alarm against a missed alarm on the pump.
What you will be able to do
Why it matters
A score with a reason survives an audit, and a register with realistic scores shows where to act first.
Practice: Practice: Risk: severity and probability · 3 questions
Sets out top management's four duties under ISO 14971 and the policy that decides which risks are acceptable.
Opens with a board that demands zero risk. Covers the four duties ISO 14971 gives top management: adequate resources, competent people, a documented policy for acceptable risk, and review of the risk process at planned intervals. Explains what the policy rests on, regulations, relevant standards, the state of the art and stakeholder concerns, and the three approaches a policy can name. Shows why zero risk is not a usable rule.
What you will be able to do
Why it matters
A clear policy lets the team apply the same rule every time, and lets management show an auditor how it was set and reviewed.
Practice: Practice: Top management and the policy · 3 questions
Explains why acceptability criteria are fixed in the plan before scoring, and walks through Sterling's recommended severity, probability and matrix.
Uses a school trip to show why rules must be agreed before the event. Explains that criteria sit in the risk management plan, including a rule for risks whose probability cannot be estimated. Presents Sterling's recommended five-point severity and probability scales and four bands, low, medium, high and critical, and why the number is a shortcut while the plan decides. Examples come from Penang, Dublin and Pune.
What you will be able to do
Why it matters
Criteria set in advance keep decisions objective, and an auditor can check their dates against the scoring.
Practice: Practice: Risk acceptability criteria and the matrix · 3 questions
Covers the competence risk work needs and the seven things a risk management plan must contain, including who approves the report.
Starts with a pump release stalled because the plan named no one with authority. Covers competent people and the knowledge a risk team usually draws from several functions. Lists the seven plan items, from scope and responsibilities to market information, and notes that a plan can grow if changes are recorded. Ends with Sterling's one-page plan outline of six headings.
What you will be able to do
Why it matters
Settling who decides before the work starts avoids last-minute delays at release.
Practice: Practice: Competence and the risk management plan · 3 questions
Describes the risk management file and the traceability it must give from each hazard to analysis, evaluation, controls and residual risk.
Opens with a regulator asking to trace one hazard of a self-test, and the days it took to assemble the answer. Defines the risk management file, the six kinds of record it typically holds, and the four traces required for every hazard. Explains that the file can point to records in the quality system rather than copy them, using a car service book as the picture, and shows how a Dublin pump row with no test link is fixed.
What you will be able to do
Why it matters
A file built for traceability turns a three-day search into a three-minute answer when a regulator picks one hazard.
Practice: Practice: The risk management file and traceability · 3 questions
Shows how a risk analysis starts: what it covers, what its record must show, and when an analysis of a similar device can be reused.
Uses version two of an insulin dose app to ask when similar is good enough. Lists the four steps of a risk analysis and the minimum record: the device, who carried it out, the scope and the date. Explains that a similar device's analysis is a starting point only after the differences are checked systematically, and that scope can be broad for a new device or narrow for a change such as a new battery supplier.
What you will be able to do
Why it matters
Checking what is new before reusing old work stops the hazards a new version brings from being hidden.
Practice: Practice: Starting a risk analysis · 3 questions
Describes intended use through six elements and shows how to find reasonably foreseeable misuse by real users, lay or professional.
Opens with self-test results read at forty minutes instead of fifteen. Lists the six elements that describe intended use, from medical indication to operating principle, and defines reasonably foreseeable misuse. Covers lay and professional users, why a leaflet saying do not does not remove a predictable misuse, and the link to the use specification from IEC 62366-1, which ISO 14971 names. Examples include the scalpel, the dose app and a home blood-pressure cuff.
What you will be able to do
Why it matters
Misuse you could have predicted is yours to analyse, and finding it early keeps it from returning as a complaint.
Practice: Practice: Intended use and foreseeable misuse · 3 questions
Shows how to identify the characteristics of a device that could affect safety, in words and numbers, and record their limits.
Starts with a design review where only the blade is named as affecting safety. Explains qualitative and quantitative characteristics and why limits matter. Presents Sterling's six questions: energy, body contact, decisions, users, software and data, and life. Applies them to the Penang scalpel and the Dublin pump, mentions essential performance, a term also used in IEC 60601-1, the electrical safety standard for medical equipment, and tests the questions on the Pune dose app.
What you will be able to do
Why it matters
A complete list of characteristics leads to the hazards that would otherwise go unanalysed.
Practice: Practice: Characteristics related to safety · 3 questions
Shows how to find hazards using the two Annex C checklists: three groups of hazards and ten categories of events and circumstances.
Opens with a pump hazard hunt that found nine hazards, almost all electrical. Explains what ISO 14971 asks: known and foreseeable hazards in normal and fault conditions, with their sequences of events. Presents the two Annex C checklists, the first of energy, biological and chemical, and performance-related hazards, and the second of events and circumstances, including use error and security. Applies both to the pump, scalpel and self-test, and crosses them.
What you will be able to do
Why it matters
Running both checklists answers the auditor's question of how you know the hazard list is complete.
Practice: Practice: Finding hazards: the Annex C checklists · 3 questions
Covers the techniques that find hazards, starting from experience, and why working backwards from harm is not enough on its own.
Starts with a workshop that worked backwards from an overdose and found eight routes. Starts with both Annex C checklists, then covers experience with the same and similar devices, including other makers' reports, then working backwards from the harm and its stated limit. Presents Sterling's combination of a step-by-step failure analysis known as FMEA, a top-down tree and a structured team walk-through, how to fit techniques to new or changed devices, and how detection is treated.
What you will be able to do
Why it matters
Choosing methods for a reason finds hazards a single technique cannot see, and answers an auditor who asks about method.
Practice: Practice: Hazard-hunting techniques · 3 questions
Defines use error, separates it from malfunction, and shows the usability events to look for and how usability links the two standards.
Opens with nurses keying zero point five and seeing five on a pump. Defines use error without blame and contrasts it with malfunction. Covers the usability entries in the events checklist and the difference between a slip, a lapse and a mistake, with an example from each of the four course devices and a home blood-pressure monitor. Notes that ISO 13485 lists usability among design inputs, that both ISO 13485 and ISO 14971 point to IEC 62366-1, and why training alone rarely fixes these errors.
What you will be able to do
Why it matters
Treating user error as where the analysis starts leads to design fixes that keep working, however well users are trained.
Practice: Practice: Use error and usability · 3 questions
Explains how software, data, security and in vitro diagnostics are handled by the same ISO 14971 process and register as any other device.
Opens with a silent overnight update that switches the units in a dose app. Confirms that software and in vitro diagnostics are in scope of ISO 14971, covers data as a hazard in five forms, and security weaknesses as events that start a chain. Looks at wrong results from diagnostics, builds three example rows, and distinguishes the device's own software from the software the quality system relies on, validated in proportion to risk, which are ISO 13485 requirements.
What you will be able to do
Why it matters
Handling a silent data error or an unchecked update like any other risk keeps it from being treated as only an IT problem.
Practice: Practice: Software, data, security and IVDs · 3 questions
Shows how to estimate risk using available data, record the scoring system, and handle a probability that cannot be estimated.
Opens with a new test line that has no field data and a manager who says just put two. Lists what the standard asks and the eight sources of information, from published standards to external quality assessment schemes. Covers quantitative and qualitative estimates, random against systematic software faults, and a worked row for late reading of the self-test on Sterling's per-use scale. Ends with the rule of listing consequences when probability is unknown.
What you will be able to do
Why it matters
A probability with a source, or a declared unknown, will survive an audit or a complaint.
Practice: Practice: Risk estimation with data · 3 questions
Covers risk evaluation: comparing each risk with the plan's criteria, deciding, and recording the decision and reason, including accepted risks.
Opens with a register row that says only accepted. Explains the three moves of evaluation, the two paths that follow, acceptable risks becoming residual risk and the others going to control, and the four items a record should show. Shows evaluation per hazardous situation, a trap where acceptance depends on an unrecorded feature, Sterling's trigger for each matrix band, and four Penang rows.
What you will be able to do
Why it matters
An accepted risk with a recorded reason can be checked by anyone, unlike a row that just says accepted.
Practice: Practice: Risk evaluation · 3 questions
Explains the order for choosing risk controls: inherently safe design first, protective measures second, information for safety last.
Uses a kitchen with hot oil and a small child to show three kinds of control. Sets out the order ISO 14971 gives and its reasons: design is built in, guards can fail or be bypassed, and information may not be followed. Shows the three options for the pump, the scalpel and a moulding line, notes that training is information, and names three common traps and when benefit-risk analysis comes in.
What you will be able to do
Why it matters
A design fix stops the complaints and field actions that a warning label alone cannot.
Practice: Practice: The risk control option order · 3 questions
Shows how risk control reaches the factory floor and the supply chain, and how every control is recorded with its type, owner and evidence.
Starts with a release agent leaving an oily film on scalpel handles at a contract moulder in Manila. Covers manufacturing risks, contamination, residues and mix-ups, controlled in the same order as design. Explains how relevant standards help define controls, such as ISO 10993-1 for biological evaluation, which ISO 14971 names, and gives a typed control for each of the four devices. Includes a sterilising service and a distributor's cold room, and the three things recorded for each control.
What you will be able to do
Why it matters
Typing and owning every control shows at a glance when a row depends only on words.
Practice: Practice: Risk control in practice · 3 questions
Explains the two separate verifications every risk control needs: that it is implemented, and that it is effective, with records for both.
Opens with a warning added to a self-test box and a quality manager asking how it is known to work. Distinguishes the two verifications ISO 14971 asks for, implementation and effectiveness, using a smoke alarm as the picture. Covers where evidence comes from, including design verification, process qualification and usability tests, how much effort is enough, and examples for a pump alarm and the self-test warning, where a timer was added after the test.
What you will be able to do
Why it matters
A control with both records can be defended in the market, while one without an effectiveness record is only a hope.
Practice: Practice: Implementing and verifying controls · 3 questions
Explains residual risk and the loop of re-scoring after a control, then checking whether the control created new hazards.
Returns to the kitchen, where a child gate traps a grandmother with a walking frame. Defines residual risk as the risk that remains after controls and shows the required steps: implement, verify, evaluate against the criteria and record, looping back if not acceptable. Explains which score usually moves, and the review for new hazards, with the scalpel spring, the dose cap and a pressure relief valve as examples.
What you will be able to do
Why it matters
Looking for the side effects of each fix keeps the same complaints from returning in a different form.
Practice: Practice: Residual risk and risks from controls · 3 questions
Explains benefit-risk analysis: its two triggering conditions, what counts as a benefit, and why business reasons can never be weighed.
Uses a long flight to meet a grandchild to show reducing risk first, then weighing what remains. Defines a benefit in terms of health, patient management or public health. Covers when the analysis applies, when a residual risk is not acceptable and further control is not practicable, with the pump and the self-test as cases, and why cost, speed to market or a competitor's price are excluded.
What you will be able to do
Why it matters
Used in its place, after every practicable control, benefit-risk is a defensible decision rather than an excuse.
Practice: Practice: Benefit-risk analysis · 3 questions
Covers the completeness review that closes risk control, checking that every hazardous situation was considered and every control finished.
Opens with a time-zone row listed in a workshop but never scored. Explains the review the standard requires, why it covers all rows including accepted ones, and Sterling's six-point checklist run row by row. Highlights the to-do-later row as a sign that risk control is incomplete, and shows three gaps found in a final review of the dose app, then a Dublin register with four rows marked to follow.
What you will be able to do
Why it matters
A deliberate review finds the unfinished rows before a patient does.
Practice: Practice: Completeness of risk control · 3 questions
Builds a full risk register for the infusion pump row by row, in four parts, and shows how to read a row aloud as one sentence.
Presents Sterling's register in four parts: hazard information, initial risk, controls and residual risk. Builds six pump rows with scores, controls, verification and residual risk, and contrasts a weak line with a strong one. Lists four weaknesses to check for in your own register: everything scored five, training as the only control, no misuse, and never updated. Introduces the optional workbook on the self-test.
What you will be able to do
Why it matters
The register is the first thing an auditor asks for, and strong rows keep one weak row from undermining the rest.
Practice: Practice: The register, end to end · 3 questions
Covers evaluating the overall residual risk of the whole device against its benefits, and disclosing significant residual risks to users.
Uses a toddler's summer stay with her grandparents to show why every risk being acceptable does not make the whole acceptable. Explains clause eight of ISO 14971, the overall residual risk evaluated by the method in the plan, and the three elements such a method can include. Covers disclosure of significant residual risks in the accompanying documentation, what to do if the overall risk is not acceptable, and the self-test and pump as cases.
What you will be able to do
Why it matters
Judging the whole device, then telling users what remains, covers risks that no single row shows.
Practice: Practice: Overall residual risk and disclosure · 3 questions
Describes the risk management review before commercial release and the report that records it, with the three checks the review must cover.
Opens with a scalpel release held up by an unsigned report. Explains clause nine of ISO 14971 as a gate before release, the three checks, that the plan was carried out, that the overall residual risk is acceptable and that methods exist for production and market information, and who carries out the review. Shows what the report is, Sterling's four-section outline, the Penang reviewer's questions and a self-test report that omits market information.
What you will be able to do
Why it matters
The review and the signed report are the last safety net before a device reaches a patient.
Practice: Practice: Risk management review and report · 3 questions
Shows how to set up an active system to collect production and post-production information from six sources, and the triggers that follow.
Opens with three messages in one week, from a distributor, a service partner and a journal, landing in different inboxes. Explains that the maker must establish and maintain a documented system, and lists the six sources, including the state of the art. Covers public information about similar devices, ownership of each source, and Sterling's six triggers: a complaint, a trend, a change, new rules, outside news and the calendar. Notes the matching parts of ISO 13485: design inputs, feedback, data analysis and improvement.
What you will be able to do
Why it matters
Collecting information actively turns scattered messages into decisions instead of waiting for a problem to arrive.
Practice: Practice: Collecting production and market information · 3 questions
Covers reviewing collected information with four questions, and the actions on the device and on the risk management process that follow.
Opens with twelve similar complaints about an app, each closed one by one. Sets out the four review questions: new hazards, a risk no longer acceptable, the overall residual risk and the state of the art. Covers actions on the device, including devices already on the market, then actions on the risk management process itself, and shows what belongs to ISO 13485 rather than ISO 14971: complaint handling, regulator reporting and corrective action.
What you will be able to do
Why it matters
Putting similar complaints side by side finds the pattern before a regulator or a patient does.
Practice: Practice: Reviewing information and acting · 3 questions
Shows how making, testing and shipping a device can switch a hazard back on, and how to score and control process risk.
Opens with a sterilisation temperature sensor reading high at the contract steriliser in Manila. Separates product risk from process risk and gives Sterling's chain of step, failure and effect, linked to the product hazard. Scores the sensor failure on the same matrix, then covers the control order for processes and three ISO 13485 requirements: process validation, calibration and training. Ends with a supervisor who skips a final test.
What you will be able to do
Why it matters
One process failure can affect a whole batch, so linking the process and product registers protects every patient who receives it.
Practice: Practice: Process risk on the shop floor · 3 questions
Covers how outsourcing, supplier choice and change reach the risk file, including supplier tiers and a risk gate on every change form.
Opens with a cheaper blade supplier offered as the same blade. Explains that the maker keeps responsibility for outsourced processes, controlled through written quality agreements, and that supplier controls follow risk. Presents Sterling's three supplier tiers, critical, important and standard, the kinds of change that create new hazards, such as a new skin-contact material needing biological evaluation under ISO 10993-1, and ISO 13485's review of design changes, and the gate where no change is released until the risk file has been reviewed. Ends with a distributor and a warm warehouse.
What you will be able to do
Why it matters
A risk gate on every change form stops cost-saving changes from switching a controlled hazard back on.
Practice: Practice: Suppliers, outsourcing and change · 3 questions
Looks at risk management through an auditor's four questions, each role's part, and the whole course as one loop.
Opens with an auditor who picks one row of a three-hundred-row register and follows it. Gives four questions that cover most of an audit, then four scenes from the line, the warehouse, a service van and a design office. Sets out the part played by operators, testers, supervisors, engineers, quality and management, recaps the course as plan, analyse, evaluate, control, review and the market, and closes with the final exam and Certificate of Completion.
What you will be able to do
Why it matters
If one row can survive an auditor's follow-through, trust in the whole file grows.
Practice: Practice: The auditor's view and your part · 3 questions
Your certificates

Verifiable certificate with a QR code anyone can scan, plus a digital badge to add to your LinkedIn profile.
See how verification works →You will be able to apply ISO 14971:2019 Medical Device Risk Management at work and show your competence with confidence. Your certificate can be verified online in seconds, so certification body auditors, employers and clients can confirm your training instantly.
Complete the course and its final exam and you receive a Sterling Academy Certificate of Completion, verifiable online by QR code, with a LinkedIn badge to share.
Who built this course
Sterling has 20+ years and 8,100+ client engagements in 60+ countries. The course is built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC, on the current edition of the standard. Online and self-paced, built the way we build our classroom training: the same content and format as Sterling’s classroom courses, whose certificates are trusted and accepted by all major certification bodies.
Prepared by the Sterling expert panel · Last updated 3 October 2026 · How our courses are made
Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.
Who it is for
Risk, design, software, quality and regulatory teams of device manufacturers, contract manufacturers and distributors.
Training a team? Every learner gets their own access and certificate, and the client administrator sees each person’s progress and result in one place.
Part of the ISO 13485:2016 learning path → Step 2
Is competence and training mandatory under the FDA QMSR?
Is training mandatory under the EU Medical Devices Regulation (MDR)?
Is training mandatory under ISO 13485?
Terms in this course: Residual risk · Risk management file
About this course
The risk management file is central because it is the traceable record showing that every known hazard was identified, assessed, controlled and accepted against defined criteria. ISO 14971 sets out a process for managing risks across a device's whole life cycle, including software as a medical device and in vitro diagnostic devices. It requires the manufacturer to set objective criteria for risk acceptability, but it does not tell the manufacturer what level of risk is acceptable; that policy belongs to top management. Reviewers, notified bodies and auditors use the file to follow a line from a hazard to its controls, their verification and the final residual risk. A file assembled at the end of design, rather than grown alongside it, usually shows gaps in that trace. The course explains how to plan, structure and maintain the file so it stays useful after release.
You trace a hazard to harm by describing the sequence of events that turns a potential source of harm into a hazardous situation and then into injury. Take an infusion pump: the hazard is energy delivered as drug flow; a sequence of events, such as an occlusion alarm not sounding while a line is kinked, creates a hazardous situation in which the patient receives no drug; the harm is a deterioration in the patient's condition. Risk combines the severity of that harm with its probability of occurring, which often needs separate estimates for the sequence and for the harm. Intended use, reasonably foreseeable misuse, use error, software behaviour, data and cybersecurity all add sequences worth analysing. The course uses the checklists and hazard-hunting techniques teams rely on, so that the analysis covers the device as people actually use it.
Risk control options are taken in a fixed order: inherently safe design first, then protective measures in the device or its manufacture, and only then information for safety. A design change that removes a pinch point is preferred to a guard, and a guard is preferred to a warning label or a training slide. Each chosen control must be implemented and then verified twice: that it is actually in the device, and that it reduces the risk as intended, for example through testing or a usability study. New risks introduced by a control, such as an extra alarm that adds alarm fatigue, are analysed too. Teams often skip the effectiveness step or rely too heavily on labelling, and auditors look for exactly that. The course works through a full risk register, showing how each line moves from analysis to control and verified residual risk.
The 2019 edition places greater emphasis on benefit-risk analysis and on production and post-production activities. When a residual risk is not acceptable under the manufacturer's criteria and further control is not practicable, the team may judge whether the medical benefit outweighs that risk, and the reasoning must be documented. Once the device is on the market, the work continues: complaints, service reports, field data, published literature and information about similar devices are collected and reviewed for new hazards or changed probabilities. If that review shows a problem, the file is updated and actions follow. The edition remains current, and ISO confirmed it in 2025. The course covers the overall residual risk evaluation, disclosure of residual risks, the risk management review and report, and how production processes, suppliers, outsourcing and change feed back into the same file.
Design, risk, software, quality and regulatory staff at manufacturers, contract manufacturers and distributors should take this course when they write or review risk files. In practice, risk management runs through a device quality system as one thread, and auditors of an ISO 13485 system routinely follow it into design, purchasing, production and complaint handling. Teams building that quality system should add ISO 13485:2016 Implementation Training, and design engineers can take Design Controls for Medical Devices. Software developers will find Software as a Medical Device and IEC 62304 Training a natural next step, while pharmaceutical teams looking for the equivalent risk approach should consider ICH Q9 Quality Risk Management. Device teams spread across sites can study online at their own speed while receiving the same content and format as Sterling's classroom training, and an auditor can verify the certificate through its QR code.
Save when you learn more
Course passes
Also in the All-Access Pass: all 210 courses except Lead Auditor courses for US$499, about the price of 5 courses.
Compare the passesFor teams
From US$69 per learnerEach learner gets their own access and certificate; you see progress in one place.
Price your team →Save when you take more than one course
The discount is added automatically in your basket.
What learners say
Every course is built by the experts behind 8,100+ client engagements in 60+ countries, so you learn what auditors and regulators actually expect. Here is what professionals said after finishing their course.
Informative
10/10 for Philippines Data Privacy Act and DPO Training
Better value
All-Access Pass
A pharma and life sciences professional from the USA started with one course, then upgraded to the All-Access Pass.
Every Sterling Academy course except Lead Auditor courses, for 12 months.
US$499
See the passA selection of comments from learners who finished a course and answered our feedback request, shortened from their own words. Client names available on request.
Frequently asked questions
About ISO 14971:2019 Medical Device Risk Management, its certificate and enrolment.
Ask SterlingYes. Sterling Academy's ISO 13485 courses are built by the Sterling consulting group, which has taken organisations to certification across 8,100+ client engagements in 60+ countries over 20+ years. They cover the awareness, implementation, internal auditor and specialist levels, always on the current edition, with practice questions that show the right answer. Each course ends with a final exam and a certificate that anyone can verify online, plus a LinkedIn badge, and client administrators can show an auditor exactly who has been trained. You will be able to apply ISO 14971:2019 Medical Device Risk Management at work and show your competence with confidence. Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.
Awareness: ISO 13485:2016 Awareness · Implementation: ISO 13485:2016 Implementation Training · Internal auditor: ISO 13485:2016 Internal Auditor Training · Specialist: ISO 14971:2019 Medical Device Risk Management
It is for the people who build and maintain a medical device risk management file: risk management, design, R&D and software engineers, and quality and regulatory staff of device manufacturers. It also suits production and supplier-quality leads, contract manufacturers, importers and distributors, whose work feeds the file, and top management, who set the policy for risk acceptability. No prior knowledge of ISO 14971 is needed; ISO 13485 awareness helps.
It covers the scope of ISO 14971:2019 and its link with ISO 13485:2016; hazards, hazardous situations, harm and risk; the policy for risk acceptability, the plan and the risk management file; risk analysis, including intended use, foreseeable misuse, use error, software and data; risk evaluation and control in the standard's order; residual risk, benefit-risk analysis and overall residual risk; the risk management review; and production and post-production information, process risk, suppliers and change.
It is a set of short video modules, each followed by practice questions, and a final exam. The course page shows the number of modules and the approximate video runtime; allow additional time for the practice questions and the exam. With 12 months of access, you can complete it in one sitting or spread it over several sessions.
Yes. Learners who reach the 70% pass mark in the final exam receive a Sterling Academy Certificate of Completion for ISO 14971 Medical Device Risk Management. Each certificate carries a unique number and a QR code, and anyone can verify it online using the certificate number and the holder's surname. It is a training certificate for the individual learner.
Yes. ISO 14971 Medical Device Risk Management is a self-paced online course made of short video modules, in English with captions. You study at your own pace during 12 months of access, and practice questions after modules help you check your understanding before the final exam. If a point is unclear, questions are answered by a Sterling consultant.
ISO 14971 Medical Device Risk Management has a list price of US$149 per learner, with a limited-time offer of US$99 per learner until 31 December 2026. Teams save 20% for 11 to 50 learners and 30% for 51 to 200; 201 or more learners are priced on request. Client administrators can track their team's progress. Prices are in US dollars, excluding taxes, and Sterling confirms final pricing and enrolment.
It gives your people the knowledge ISO 14971 or ISO 13485 asks of them, and each learner's verifiable certificate is evidence of that training when the auditor asks. The Certificate of Completion is a training certificate: it shows that one person completed ISO 14971 Medical Device Risk Management and reached the pass mark in its final exam. Where an organisation seeks certification, for example of its ISO 13485 quality management system, which requires documented risk management, it is certified by an independent certification body after that body's own audit.
Your next step
Not sure which course?