EU MDR Training: Regulation (EU) 2017/745 Awareness for Your Whole Team

Part of the ISO 13485:2016 learning path → Step 2

EU MDR training for people who work with medical devices and keep hearing about classes, notified bodies, EUDAMED and transition deadlines without a clear picture of what it all means for their own job. You may have joined a device manufacturer, importer or distributor, been asked to support an MDR project, or need to answer a customer or notified body question without calling regulatory affairs every time.

This training course explains Regulation (EU) 2017/745 in plain language: who the economic operators are and what each must do, how devices are classified and certified, what the technical documentation and clinical evaluation contain, how UDI, EUDAMED and vigilance work, what the IVDR adds and which dates still matter. You follow an orthopaedic implant maker in Amsterdam, so each rule shows up in a real business.

EU MDR training explains Regulation (EU) 2017/745, the law that governs placing medical devices on the EU market. An awareness course covers scope and definitions, the roles of manufacturers, authorised representatives, importers and distributors, classification, conformity assessment and CE marking, technical documentation, clinical evaluation, UDI and EUDAMED, post-market surveillance, vigilance and the transitional provisions.

Training a team? Get a quote for your organisation

Part of: Medical Device Quality and Risk Management Training

Part of: GMP & Medical Devices

Secure payment by Stripe · for yourself or for your team

What you get

  • 11 video modules

    About 117 minutes, with captions. Watch at your own pace on any device.

  • Practice after every module

    Short questions check your understanding before you move on.

  • Final exam

    Multiple choice, with immediate retakes if you need them.

  • Built by experts

    Industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC.

A certificate you can prove, and share

Verifiable certificate with a QR code anyone can scan, plus a digital badge to add to your LinkedIn profile.

See how verification works →

Standard and editionRegulation (EU) 2017/745 on medical devices

Last updated31 October 2026

Why the EU MDR matters now: deadlines and EUDAMED

The MDR has applied since 26 May 2021, but for many companies the hardest dates are still ahead, and the rules keep moving.

In March 2023, the EU extended the transition for legacy devices because notified body capacity was insufficient and there was a risk of shortages of devices. Devices still on the market under the old directives may stay only until 31 December 2027 or 31 December 2028, depending on their class, and only if the manufacturer met the conditions: a quality management system to the MDR, a formal application to a notified body by 26 May 2024 and a written agreement by 26 September 2024. Missing those conditions means the device cannot use the extension.

In November 2025, the European Commission declared the first four EUDAMED systems functional, covering actor registration, UDI and device registration, notified bodies and certificates, and market surveillance. Their use became mandatory from 28 May 2026. In June 2024 the EU also added a duty for manufacturers to warn in advance of an interruption or discontinuation of supply. If your team does not know these dates, the risk is a device that cannot legally be sold.

Who this EU MDR training course is for

The course is for anyone whose work touches a medical device placed on the EU market, not only regulatory specialists.

You need it when you join a device company, when your company starts exporting to the EU, when a notified body audit or MDR project is under way, or when your role as importer or distributor brings new legal duties you have to understand.

  • Staff of medical device manufacturers in quality, regulatory, R&D and production
  • Importers, distributors and authorised representatives and their teams
  • Sales and supply-chain teams who handle labelling, UDI and supply notices
  • Managers preparing to place devices on the EU market for the first time
  • New starters who need a clear overview before specialist training

What you will learn

You finish with a clear picture of how the MDR works from start to finish and where your own job fits.

  • Explain the purpose and scope of the EU MDR and the roles of economic operators
  • Describe how devices are classified and which conformity assessment routes apply
  • Recognise the general safety and performance requirements and technical documentation
  • Explain clinical evaluation, UDI and the role of EUDAMED
  • Describe post-market surveillance, vigilance and the person responsible for regulatory compliance
  • Understand the transitional provisions and how to follow changes to the Regulation

Course outline: 11 modules

The course follows the life of a device, from what counts as a medical device to what happens after it is on the market.

  • Module 1, The EU MDR at a glance: why the MDR replaced the directives, how it developed, the company you follow and how you learn.
  • Module 2, Scope, definitions and non-medical products: what counts as a medical device, key definitions, exclusions and Annex XVI products without a medical purpose.
  • Module 3, Manufacturers, importers and distributors: the four economic operators, their duties, when you become the manufacturer, and supply notices.
  • Module 4, Classification: the four risk classes, how the Annex VIII rules work, implants, software and common mistakes.
  • Module 5, Conformity assessment and CE marking: routes by class, notified bodies, the declaration of conformity and CE marking.
  • Module 6, Safety and performance, technical documentation: the general safety and performance requirements, risk management, the label and instructions, and the technical file.
  • Module 7, Clinical evaluation and the QMS: clinical evaluation and investigations, follow-up after launch, the public summary and the quality management system.
  • Module 8, UDI, EUDAMED and registration: unique device identification, the Basic UDI-DI, implant cards, registration and EUDAMED.
  • Module 9, Post-market surveillance, vigilance and the PRRC: surveillance, periodic safety update reports, vigilance, field safety actions and the person responsible for regulatory compliance.
  • Module 10, In vitro diagnostic devices, the IVDR: what Regulation (EU) 2017/746 covers, classes A to D, routes, evidence, in-house tests and dates.
  • Module 11, Transition, enforcement, changes and the exam: legacy devices, enforcement and penalties, how changes are made, your role, and the final exam.

Regulation (EU) 2017/745 explained

The EU Medical Device Regulation was adopted on 5 April 2017 and has applied since 26 May 2021, after a one-year postponement because of COVID-19. It replaced the Medical Devices Directive and the Active Implantable Medical Devices Directive, and it applies directly in every Member State. The course teaches the consolidated text in force in October 2026, including the amendments on transition, EUDAMED and supply interruptions.

It applies to manufacturers, authorised representatives, importers and distributors of medical devices, and to certain products without a medical purpose listed in Annex XVI. Devices fall into four classes, I, IIa, IIb and III, set by the 22 rules of Annex VIII; when more than one rule applies, the strictest one decides. The class sets the conformity assessment route, from self-declaration for most class I devices to notified body certification for higher classes.

The main parts you will meet are the general safety and performance requirements of Annex I, technical documentation, clinical evaluation, the quality management system, UDI and registration in EUDAMED, post-market surveillance and vigilance, and the person responsible for regulatory compliance required by Article 15. In vitro diagnostic devices have their own law, the IVDR, which the course introduces in Module 10.

How the course works

The course is 11 on-demand video modules, about 2 hours of video in total. Each module explains the rules with examples from the Amsterdam implant maker and from other companies across Europe, shows a common mistake and what good practice looks like, and ends with practice questions so you can check your understanding.

At the end you take a scenario-based multiple-choice final exam drawn from the course's question bank. Complete the course and its assessed final exam (pass mark 70%, one retake included) and you receive a Sterling Academy Certificate of Completion. You study online, on any device, at your own pace.

What you can do after the course

Awareness pays off in everyday decisions.

  • Tell whether a product is a medical device, an accessory or an Annex XVI product
  • Recognise when your company acts as manufacturer, importer or distributor, and what each role must check
  • Read a device's class and conformity route and understand why a notified body is involved
  • Find the right information in the technical documentation, the label and the UDI
  • Report a complaint or possible incident quickly to the right person for vigilance
  • Explain to colleagues and customers which transition dates apply to your legacy devices

For teams and organisations

MDR compliance depends on many people knowing the basics, from R&D to the warehouse. A company plan lets a client administrator add staff, assign courses and follow progress reports, with one invoice for your organisation.

Get a quote for your organisation and tell us how many people you want to train.

Why Sterling Academy

Sterling Academy courses are built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC. The Academy is the training arm of Sterling International Consulting, with 8,100+ client engagements in 60+ countries over 20+ years.

Every course teaches the current text. This one follows the consolidated MDR in force in October 2026 and the latest consolidated IVDR, with the extended transition, the EUDAMED decision of November 2025 and the March 2026 lists of well-established technologies.

Preview this course

Experience the learning
before you enrol.

Watch a sample from EU MDR Awareness (Regulation (EU) 2017/745) before you enrol.

EU MDR Awareness (Regulation (EU) 2017/745)Sample

Inside the course

A clear path through the essentials.

11 modules, 11 practice checkpoints and a final exam. Video runtimes are approximate; allow additional time for the practice questions and the final exam. Modules marked optional can be skipped; the others are studied in any order.

Part 1What the MDR is and what counts as a medical deviceApprox. 20 min

  1. The EU MDR at a glance9 min

    An overview of the EU Medical Device Regulation (EU) 2017/745: why the MDR exists, how it developed, its transition and Eudamed, and the course.

    What this module covers

    Opens with a self-check: how would you rate your knowledge of the EU device rules, what makes a product a medical device, and which part of a device's life your role touches. Then the June 2012 European Parliament resolution on defective silicone breast implants, with about 400,000 sold worldwide and no EU-wide register, and its call for stronger notified bodies, vigilance and a European database. Explains how the MDR replaced two directives with one regulation, its application since May 2021, the 2023 extension of the transition and Eudamed coming into use module by module. Introduces Canal Orthopaedics B.V., an implant maker in Amsterdam with a distributor in Madrid and hospitals in Paris, plus a wound-dressing maker in Mumbai and a health-app developer in London. Closes with a recap and how the eleven modules and exam work.

    What you will be able to do

    • Explain why the EU replaced the device directives with the MDR
    • Describe the MDR's main dates, from application to the transition
    • Identify which part of a device's life your own role touches

    Why it matters

    Being able to say how your company knows its device is safe, and who checked, starts with knowing what the MDR asks.

    Practice: Practice: The EU MDR at a glance · 3 questions

  2. Scope, definitions and non-medical products10 min

    What counts as a medical device under the EU MDR: the definition, intended purpose, exclusions and Annex XVI products without a medical purpose.

    What this module covers

    Begins with a distributor in Milan asked whether a fitness tracker, a dose-calculating smartphone app and coloured fashion contact lenses fall under the MDR. Explains the definition of a medical device in plain words, from instruments and software to implants, and why the purpose the manufacturer gives a product decides, not how it looks. Covers how that purpose shows in the label, instructions, sales material and clinical evaluation, and why Canal Orthopaedics puts nothing in a brochure the clinical evaluation does not support. Sets out what the MDR excludes, such as in vitro diagnostics, medicines, cosmetics and food, and the six Annex XVI groups it brings in, with a posture app in Dublin and light equipment for salons from a Paris supplier. Explains the common specifications applying from 22 June 2023, and closes with a recap.

    What you will be able to do

    • Decide whether a product is a medical device from its intended purpose
    • Identify the main product types the MDR excludes
    • Recognise Annex XVI products the MDR covers without a medical purpose

    Why it matters

    The purpose you claim decides the rules you meet; a single sales claim can turn a wellbeing product into a medical device.

    Practice: Practice: Scope, definitions and non-medical products · 3 questions

Part 2Economic operators, classification and conformity assessmentApprox. 33 min

  1. Manufacturers, importers and distributors11 min

    EU MDR economic operators explained: duties of manufacturers, authorised representatives, importers and distributors, and supply interruption notice.

    What this module covers

    Opens with wound dressings from a Mumbai maker going through an authorised representative in Dublin, an importer in Frankfurt and a distributor before reaching a hospital in Paris. Defines the four economic operators as Article 2 does, then the manufacturer's duties, the sole authorised representative needed by a maker outside the EU and its liability, and the checks importers and distributors make. Shows when someone else becomes the manufacturer, as when a Milan distributor sells gloves under its own brand. Covers the duty added in 2024 to give notice of a supply interruption that could cause serious harm, normally six months ahead, with a Lisbon catheter maker. Applies it all to Canal Orthopaedics, established in the Netherlands, and its distributor in Madrid checking the CE marking, declaration, labels and UDI. Closes with a recap.

    What you will be able to do

    • Identify the four economic operators and the duties of each
    • Recognise when a distributor takes on a manufacturer's obligations
    • Explain when notice of a supply interruption is required

    Why it matters

    If each company in the chain assumes another one checked, nobody does; knowing your role keeps unsafe devices from patients.

    Practice: Practice: Manufacturers, importers and distributors · 3 questions

  2. Classification11 min

    Medical device classification under EU MDR Annex VIII: classes I, IIa, IIb and III, Rule 8 for implants, Rule 11 for software, and common errors.

    What this module covers

    Starts in an operating theatre in Paris, where a Canal knee system, its reusable instruments and fracture plate screws fall into three different classes in one operation. Explains the four classes, set by intended purpose and inherent risk under the Annex VIII rules, why the manufacturer classifies its own devices, and how a dispute with a notified body is settled. Covers how duration, invasiveness and activity work across the twenty-two rules, and why the strictest rule wins. Explains Rule 8, under which implants are class IIb but joint replacements class III, and Rule 11, which classifies software by the decisions it informs. Looks at a Vienna instrument maker launching a disposable version of a reusable cutter, then the common mistakes and how to check a class against your technical documentation. Closes with a recap.

    What you will be able to do

    • Explain how intended purpose and risk set a device's class
    • Apply the implant and software rules to simple examples
    • Check a device's class against its technical documentation

    Why it matters

    The class decides the route to market and the evidence needed; getting it right first avoids costly rework later.

    Practice: Practice: Classification · 3 questions

  3. Conformity assessment and CE marking11 min

    EU MDR conformity assessment routes, notified bodies and certificates, the EU declaration of conformity, and the rules for CE marking.

    What this module covers

    Opens at Canal Orthopaedics with two launches in one month: a low-class positioning aid where Canal declares conformity itself, and a class III knee system that needs a notified body. Explains conformity assessment under Annexes IX to XI, how notified bodies are designated and what they assess, and why responsibility stays with the manufacturer. Covers Article 53 and a Frankfurt maker whose application was refused, assessment of class IIb implant documentation except well-established types such as screws and plates, and certificates valid for five years at most. Then the EU declaration of conformity, drawn up under the manufacturer's sole responsibility, the CE marking rules step by step, and an importer in Brussels checking a class IIa device. Closes with a recap: assess first, declare second, mark last.

    What you will be able to do

    • Explain how the risk class decides the conformity assessment route
    • Describe what a notified body assesses and certifies
    • Check that a device has its EU declaration and correct CE marking

    Why it matters

    The CE marking tells a hospital who stands behind a device; knowing the route behind it helps you answer their questions.

    Practice: Practice: Conformity assessment and CE marking · 3 questions

Part 3Safety, clinical evidence and traceabilityApprox. 32 min

  1. Safety and performance, technical documentation10 min

    EU MDR Annex I general safety and performance requirements (GSPRs), risk management, labels and instructions, and technical documentation.

    What this module covers

    Begins with a competent authority asking Canal for evidence that its hip stem resists fatigue: one version takes weeks from a shared drive and e-mails, the other days from organised technical documentation. Explains the general safety and performance requirements of Annex One, with risks acceptable against the benefits, and how its three chapters are organised. Covers risk management for the device's whole life, with controls in a set order, illustrated by an infusion set maker in Milan whose connector can be fitted the wrong way. Looks at labels and instructions users can understand, with a Madrid distributor receiving instructions only in English. Then the six sections of the technical documentation and how long it is kept: at least ten years, fifteen for implants, with field data fed back into the risk file. Closes with a recap.

    What you will be able to do

    • Explain what the general safety and performance requirements ask
    • Describe the order in which risk controls are applied
    • Identify what the technical documentation contains and how long it is kept

    Why it matters

    If it is not documented, it cannot be shown; organised technical documentation lets you answer an authority in days.

    Practice: Practice: Safety and performance, technical documentation · 3 questions

  2. Clinical evaluation and the QMS10 min

    EU MDR clinical evaluation, clinical investigations, post-market clinical follow-up (PMCF), the patient summary and the quality management system.

    What this module covers

    Opens at Canal with two views of the new knee system: a completed clinical study as the end of the job, or the start of evidence gathered every year after launch. Defines clinical evaluation as a planned, continuous process built on clinical data that give sufficient evidence of safety and performance, and how the level of evidence is justified. Covers the three tests for relying on another device's data, with a Copenhagen maker planning a bone anchor, and why implants and class III devices usually need clinical investigations. Explains post-market clinical follow-up with yearly updates and the summary for patients. Then the quality management system covering every aspect in Article 10, including outsourced sterilisation at a maker in Lisbon. Closes with a recap: evidence before launch, and every year after.

    What you will be able to do

    • Explain what clinical evaluation is and why it never finishes
    • Describe when clinical investigations and follow-up are needed
    • Identify what the quality management system must cover

    Why it matters

    Surgeons may spot a problem before the maker does; planned follow-up after launch keeps clinical evidence current.

    Practice: Practice: Clinical evaluation and the QMS · 3 questions

  3. UDI, EUDAMED and registration11 min

    EU MDR device traceability: UDI-DI, UDI-PI and Basic UDI-DI, implant cards, SRN registration of economic operators, and the Eudamed modules.

    What this module covers

    Starts with a possible packaging defect in one batch of Canal hip implants, and how quickly the devices and patients can be found if every link scanned the unique identifier. Explains the UDI system, the device identifier and production identifier, the UDI carrier on labels and packaging, and the Basic UDI-DI. Covers implant cards, shown arriving with knee implants at a hospital in Brussels, and storing the UDIs of class III implants. Explains registration of manufacturers, authorised representatives and importers, the single registration number issued by the competent authority, and keeping data current, as an importer in Frankfurt must after moving office. Ends with the state of Eudamed, with four systems mandatory since May 2026, a hospital in Paris linking a stem to its patient record, and a recap.

    What you will be able to do

    • Explain the parts of a UDI and what each one identifies
    • Describe how economic operators register and receive an SRN
    • Check that a device can be traced to the patient who received it

    Why it matters

    Traceability cannot be added on the day of a recall; it is built in advance, one scan at a time.

    Practice: Practice: UDI, EUDAMED and registration · 3 questions

Part 4Post-market duties, the IVDR and transitionApprox. 33 min

  1. Post-market surveillance, vigilance and the PRRC10 min

    EU MDR post-market surveillance, PSURs, vigilance reporting of serious incidents, field safety corrective actions and the PRRC role.

    What this module covers

    Opens with a surgeon in Paris reporting a hip stem that broke inside a patient, handled in one version as a complaint for next month's meeting and in the other as a possible serious incident sent at once to vigilance. Explains the post-market surveillance system, proportionate to the risk class and part of the quality management system, and the report or PSUR depending on class. Covers serious incident reporting deadlines of fifteen, ten or two days, and field safety corrective actions with a clear notice to users, using a recall in Rome hospitals. Looks at trend reporting with an adhesive dressing maker in Hamburg receiving complaints about skin reactions. Then the person responsible for regulatory compliance, the PRRC, with the expertise and protection the MDR requires. Closes with a recap.

    What you will be able to do

    • Explain what a post-market surveillance system gathers and reports
    • Apply the vigilance reporting deadlines to a field report
    • Describe the role of the person responsible for regulatory compliance

    Why it matters

    Every report from the field must be assessed fast; a slow inbox uses up time that belongs to patients.

    Practice: Practice: Post-market surveillance, vigilance and the PRRC · 3 questions

  2. In vitro diagnostic devices: the IVDR12 min

    The EU IVDR (In Vitro Diagnostic Regulation) explained: IVD scope, classes A to D, performance evaluation, notified bodies and transition dates.

    What this module covers

    Opens with Regulation (EU) 2024/1860, published in July 2024, which extended the IVDR transition again because notified body capacity was not enough and tests risked shortages. Defines an in vitro diagnostic device, from reagents, calibrators and kits to instruments, software and sample tubes. Covers the four classes A to D, why every class except A now needs a notified body, and performance evaluation as the evidence. Explains the health institution exception and how a hospital laboratory in Paris that sells its own test loses it. Sets out the transition dates as amended in 2024, running to the end of 2027, 2028 or 2029 by class, with a Frankfurt maker of urine test strips that self-declared under the old directive. Shows what the IVDR shares with the MDR, with a Madrid distributor handling both, and closes with a recap.

    What you will be able to do

    • Explain what makes a product an in vitro diagnostic device
    • Describe the four IVDR classes and which need a notified body
    • Identify the IVDR transition conditions for a device

    Why it matters

    Tests and analysers follow their own regulation and dates; knowing which applies keeps diagnostic products on the market.

    Practice: Practice: In vitro diagnostic devices: the IVDR · 3 questions

  3. Transition, enforcement, changes and the exam10 min

    EU MDR transitional provisions for legacy devices, how the MDR is enforced, proposed changes to simplify it, and the final exam.

    What this module covers

    Starts with a Canal hip stem still under an old directive certificate, and a competitor whose similar stem lost the transition because it never applied for MDR certification. Explains the 2023 amendment: legacy devices placed on the market until 31 December 2027 or 31 December 2028 by class, only if a quality management system, application and written agreement were in place in time. Covers a Warsaw maker selling a legacy class IIa device during the transition. Then enforcement by national authorities, which check, inspect, act and set penalties, the four sources to follow, including guidance from the Medical Device Coordination Group, and the proposal to simplify the MDR still in the legislative process. Returns to the opening question from Module 1, what it all means for your role, and the final exam of thirty scenario questions.

    What you will be able to do

    • Explain the conditions a legacy device must meet during the transition
    • Describe how national authorities enforce the MDR
    • Identify reliable sources for following changes to the MDR

    Why it matters

    Missing one transition condition can take a device off the market; knowing the dates protects your products and patients.

    Practice: Practice: Transition, enforcement, changes and the exam · 3 questions

Frequently asked questions

Your questions,
answered.

About EU MDR Awareness (Regulation (EU) 2017/745), its certificate and enrolment.

Ask Sterling
Is Sterling Academy a good choice for EU MDR training?

Yes. Sterling Academy's EU MDR training is built by the Sterling consulting group, which has taken organisations to certification across 8,100+ client engagements in 60+ countries over 20+ years. It is always on the current edition, with practice questions that show the right answer. Each course ends with a final exam and a verifiable certificate that anyone can check online, plus a LinkedIn badge, and client administrators can show an auditor exactly who has been trained. You will understand what EU MDR asks of you, contribute to your organisation's implementation and audit readiness, and play your part with confidence when the auditor visits. Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.

What is EU MDR training?

EU MDR training explains Regulation (EU) 2017/745, the law for placing medical devices on the EU market. This awareness course covers scope, economic operators, classification, conformity assessment, technical documentation, clinical evaluation, UDI and EUDAMED, post-market surveillance, vigilance, the IVDR and the transitional provisions, in plain language.

Who needs EU MDR awareness training?

Anyone whose work touches a device sold in the EU needs it: staff of manufacturers, importers, distributors and authorised representatives, including quality, regulatory, R&D, sales and supply-chain teams. It suits new starters and managers who need the full picture before deeper specialist training.

When did the EU MDR start to apply?

The MDR has applied since 26 May 2021. It was adopted on 5 April 2017 and was originally due to apply from 26 May 2020, but its date of application was postponed by one year because of COVID-19. It replaced the two earlier directives on medical devices and active implantable devices.

What are the EU MDR transition deadlines?

Legacy devices certified under the old directives may stay on the market until 31 December 2027 or 31 December 2028, depending on their class, but only if the manufacturer met the conditions, including an application to a notified body by 26 May 2024 and a written agreement by 26 September 2024.

Is EUDAMED mandatory?

Yes, for the first four systems. The Commission declared the actor registration, UDI and device registration, notified bodies and certificates, and market surveillance systems functional in November 2025, and their use became mandatory from 28 May 2026. Module 8 explains what this means for registration.

What is the difference between the EU MDR and the IVDR?

The MDR, Regulation (EU) 2017/745, covers medical devices; the IVDR, Regulation (EU) 2017/746, covers in vitro diagnostic devices such as test kits and reagents. The IVDR uses classes A to D and its own transition dates. Module 10 introduces it.

How long does the EU MDR course take?

The course has about 2 hours of video across 11 modules. Allow a little extra time for the practice questions after each module and for the final exam. You can complete it in one sitting or spread it over a few sessions.

Do I get a certificate?

Yes. Complete the course and the scenario-based multiple-choice final exam, drawn from the course's question bank and assessed with a pass mark of 70%, and you receive a Sterling Academy Certificate of Completion for EU MDR Awareness. One retake is included if your first attempt does not meet the mark.

How much does EU MDR training cost?

The course costs US$19 per learner, with online access on any device. Organisations that want to train many staff across departments can ask for a quote for a company plan, with a client administrator, progress reports and one invoice.

Can my team take the course together?

Yes. With a company plan, a client administrator adds your staff, assigns the course and follows their progress through reports, so everyone from R&D to the warehouse shares the same basic knowledge of the MDR. Get a quote for your organisation to start.

Your certificate

Prove what you learned.
Share it with confidence.

You will understand what EU MDR asks of you, contribute to your organisation's implementation and audit readiness, and play your part with confidence when the auditor visits. Your certificate can be verified online in seconds, so certification body auditors, employers and clients can confirm your training instantly.

Complete the course and its final exam and you receive a Sterling Academy Certificate of Completion, verifiable online by QR code, with a LinkedIn badge to share.

Pass mark
70%
Prerequisites
None

Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.