← All courses

Practitioner training · Medical device quality

MDSAP Training: Prepare Your Quality System for the Medical Device Single Audit Program

Part of the ISO 13485:2016 learning path → Step 4

If your company sells medical devices in Canada, the United States, Australia, Brazil or Japan and an MDSAP audit is on the calendar, this MDSAP training shows you what the auditing organisation will look at and how it will grade what it finds. You may be the quality or regulatory manager who has to answer for adverse event reporting in five markets, the QMS lead preparing a first audit, or the internal auditor asked to run a gap assessment.

The training course takes you through the MDSAP audit approach process by process, from Management to Purchasing, against ISO 13485:2016 and the added requirements of the five regulators. You learn how nonconformities are graded on the five-level scale and what the post-audit timeline demands. A built example, DEF Medical, a maker of patient monitors in Toronto, is audited throughout, ending in a mock MDSAP audit and a readiness plan you can copy.

MDSAP training explains the Medical Device Single Audit Program, in which one audit by a recognised auditing organisation covers ISO 13485:2016 and the device requirements of the US, Canada, Australia, Brazil and Japan. It covers the audit approach and its seven processes, the audit cycle, nonconformity grading and post-audit timelines.

Preparing a team for MDSAP? Get a quote for your organisation

Part of: Medical Device Quality and Risk Management Training

Part of: GMP & Medical Devices

Secure payment by Stripe · for yourself or for your team

What you get

  • 13 video modules

    About 3 hours, with captions. Watch at your own pace on any device.

  • Practice after every module

    Short questions check your understanding before you move on.

  • Final exam

    Multiple choice, with immediate retakes if you need them.

  • Built by experts

    Industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC.

A certificate you can prove, and share

Verifiable certificate with a QR code anyone can scan, plus a digital badge to add to your LinkedIn profile.

See how verification works →

Standard and editionMedical Device Single Audit Program (MDSAP AU P0002); ISO 13485:2016

Last updated31 October 2026

Why MDSAP readiness matters now

One MDSAP audit now stands in for several regulators' reviews, so weaknesses in complaint handling, CAPA or adverse event reporting show up everywhere at once. Health Canada has accepted only MDSAP certificates since 1 January 2019, and the US FDA may accept MDSAP audit reports as a substitute for its routine inspections. The audit approach itself was updated to version 010 in February 2026.

Recent device cases show what is at stake when these processes fail. In June 2021 Philips Respironics recalled certain ventilators, CPAP and BiPAP machines over foam breakdown, about 15 million devices worldwide; after an FDA inspection and a Form 483, a consent decree entered in April 2024 restricted production and sale of new devices at several facilities. In December 2021 Medtronic disclosed a warning letter citing risk assessment, CAPA, complaint handling, recalls and adverse event reporting. The course frames these as the questions an auditor asks, not as claims about either firm's MDSAP status.

Who this MDSAP training course is for

The course is for people who prepare a device manufacturer's quality system for MDSAP or who audit it internally. Take it when a first MDSAP audit is booked, when you move from ISO 13485 certification to MDSAP, when you add Canada, Australia, Brazil or Japan to your markets, or after an audit has raised nonconformities you need to close within the timeline.

  • Quality and regulatory affairs managers at medical device manufacturers
  • QMS leads preparing for a first MDSAP audit
  • Internal auditors of device quality systems
  • Design, production and supplier quality engineers whose processes are audited
  • Consultants supporting MDSAP readiness

What you will learn on this training course

The outcomes follow the order in which an auditing organisation works through your system, so you prepare in the same sequence.

  • Explain how MDSAP works, who takes part and how each regulator uses the audit
  • Follow the MDSAP audit approach, its sequence, processes, tasks and linkages
  • Map ISO 13485:2016 and each jurisdiction's added requirements to your quality system
  • Prepare records for adverse event reporting, advisory notices and marketing authorisation
  • Grade nonconformities on the MDSAP five-level scale and respond within the timelines
  • Build an MDSAP readiness plan and a gap assessment for your organisation

Course outline: 13 modules

  • Module 1, Why MDSAP matters: two real cases, what MDSAP is, DEF Medical, the course and four common myths.
  • Module 2, MDSAP at a glance: who takes part, how each regulator uses the audit, auditing organisations, the certificate and its scope.
  • Module 3, The audit approach and the audit cycle: the sequence, the seven processes, linkages, risk, tasks, audit time and sampling.
  • Module 4, Process 1, Management: its purpose and tasks, outsourcing, risk, records, management review and authorised shipments.
  • Module 5, Process 2, Authorisation and registration: who applies in each market, registration, listing, licences, approvals and changes.
  • Module 6, Process 3, Measurement, analysis and improvement: data sources, investigations, CAPA, nonconforming product, internal audit and review.
  • Module 7, Complaints, adverse events and advisory notices: complaint handling, reporting decisions and timeframes by market.
  • Module 8, Process 5, Design and development: choosing the project, plans, inputs, risk, validation, software, changes and transfer.
  • Module 9, Process 6, part 1: production planning, process controls, environment, validation and sterilisation.
  • Module 10, Process 6, part 2: people, measuring equipment, software, the device file, batch records, traceability and servicing.
  • Module 11, Process 7, Purchasing: who counts as a supplier, selection, control by risk, monitoring, change notice and verification.
  • Module 12, Grading nonconformities and the timeline: writing nonconformities, the two grading steps, the five-day notice and post-audit deadlines.
  • Module 13, Putting it together: a mock MDSAP audit at DEF Medical, findings, grades and your road map.

The MDSAP requirements explained

MDSAP adds no new quality system requirements of its own; it audits ISO 13485:2016 together with the existing requirements of the participating regulators: the US FDA, Health Canada, Australia's TGA, Brazil's ANVISA and Japan's MHLW and PMDA. The audit approach document organises the audit into processes, starting with Management and moving through device marketing authorisation and facility registration, measurement, analysis and improvement, medical device adverse events and advisory notices reporting, design and development, production and service controls, and purchasing.

Audits run on a three-year cycle: an initial certification audit, annual surveillance audits and a recertification audit. Nonconformities are graded from 1 to 5 in two steps, based on their impact on the quality system and on escalation rules, under the MDSAP guideline on GHTF/SG3/N19:2012. The course teaches the structure and tasks of version 009 of the audit approach, which version 010 (February 2026) kept, and points out where version 010 changed a point, such as supplier wording and US references to the QMSR.

How the online course works

The course is delivered as 13 on-demand video modules with about 3 hours of video in total. Each module ends with short practice questions so you can check your understanding before moving on; they do not count toward your result. Four practice exercises with model answers let you apply the method: a jurisdiction and registration map, a complaint reportability decision, an audit trail from a production record to the supplier, and writing and grading four nonconformities.

The course closes with a multiple-choice final exam drawn from the course's question bank. A score of 60% or more meets the criteria for the certificate. If the first attempt does not meet the criteria, one retake is included. You receive a Sterling Academy Certificate of Competence when the exam criteria are met.

  • Study online, on demand, on any device: laptop, tablet or phone
  • Learn at your own pace and replay any module
  • Practice questions after every module
  • Final multiple-choice exam with one retake
  • Certificate of Competence when the exam criteria are met

What you can do after the course

You will be able to prepare your own organisation for MDSAP the way an auditing organisation will approach it.

  • Run a gap assessment of your quality system against the MDSAP processes and tasks
  • Map which registrations, licences and reporting rules apply in each of your markets
  • Decide whether a complaint is reportable, and where, within each market's timeframe
  • Trace a production record back through traceability to the supplier, as an auditor would
  • Write a nonconformity statement and grade it on the five-level scale
  • Plan responses that meet the post-audit timeline
  • Build a readiness plan for a first or recertification MDSAP audit

MDSAP training for teams and organisations

Sterling Academy offers company plans so a whole team can take this course together. A client administrator in your organisation adds people, assigns this course and related ones, and follows progress from one place, so quality, regulatory, design, production and supplier quality staff can all work from the same method.

Progress reports show who has started, who has completed and who holds a certificate, which is useful evidence of training when an auditor or inspector asks for it. Your organisation receives one invoice for the plan instead of individual receipts. Company prices are set per organisation: get a quote for your organisation and we will reply with a plan that fits the number of learners and courses you need.

Why learn with Sterling Academy

Sterling Academy courses are built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years of experience in ISO and GRC. The Academy is the training arm of Sterling International Consulting, with 8,100+ client engagements in 60+ countries over 20+ years, so the course content reflects what auditors, inspectors and clients actually ask for in practice.

Every course is kept to the current edition of the documents it teaches, and this one tells you exactly which audit approach version it follows.

Preview this course

Experience the learning
before you enrol.

Watch a sample from MDSAP: Medical Device Single Audit Program Training before you enrol.

MDSAP: Medical Device Single Audit Program TrainingSample

Inside the course

A clear path through the essentials.

13 modules, 13 practice checkpoints, 4 practice exercises and a final exam. Video runtimes are approximate; allow additional time for the practice questions and the final exam. Modules marked optional can be skipped; the others are studied in any order.

Part 1What MDSAP is and how regulators use itApprox. 27 min

  1. Welcome: why MDSAP matters13 min

    MDSAP training: why the Medical Device Single Audit approach matters, shown by the Philips and Medtronic cases, and how this course works.

    What this module covers

    Opens with the June 2021 Philips Respironics recall of ventilators and CPAP and BiPAP machines whose sound-reducing foam could break down, affecting 15 million devices worldwide, and the FDA Form 483 that followed an inspection of a Philips site in Pennsylvania. The second case is the Medtronic diabetes business warning letter after an inspection of its headquarters in Northridge, California. Shows how complaints, risk, corrective action, recalls and reporting form one chain, and how MDSAP works from start to finish in five steps: one audit, used by five regulators, against ISO 13485 and each market's added rules. Introduces DEF Medical Inc. in Toronto, which makes bedside patient monitors and sterile blood pressure transducers for five markets. Ends with how the thirteen modules, four practice exercises and the exam work, and a recap.

    What you will be able to do

    • Explain how complaints, risk, CAPA, recalls and reporting form one chain
    • Describe how MDSAP works from application to certificate in five steps
    • State why one MDSAP audit matters to a maker selling in all five markets

    Why it matters

    Seeing how weak links surfaced at Philips and Medtronic shows why one well-prepared audit protects access to every market.

    Practice: Practice: Welcome: why MDSAP matters · 3 questions

  2. MDSAP at a glance: the regulators and the audit14 min

    MDSAP at a glance: the five regulatory authorities, observers and affiliates, auditing organisations, the MDSAP certificate and audit scope.

    What this module covers

    Starts with Health Canada's transition, announced in December 2015, from accepting both its old scheme and MDSAP certificates from 1 January 2017 to accepting only MDSAP certificates as of 1 January 2019. Explains who takes part: five members, with official observers and affiliate members around them, and how each member uses the audit under its own rules and exceptions. Covers recognition of auditing organisations as a joint exercise, and what the certificate states: that the listed sites were audited against the listed criteria for the listed scope and found to conform, while not being a marketing authorisation. Then shows how DEF Medical writes down its MDSAP scope with its auditing organisation, and how scope works for an orthopaedic implant maker in Boston selling only in the United States and Canada. Ends with a recap.

    What you will be able to do

    • Name the MDSAP members and explain how each uses the audit report
    • Explain what an MDSAP certificate does and does not mean
    • Write an audit scope that covers every market and product you supply

    Why it matters

    Your scope must match your sales; a scope that misses a market leaves a gap that a regulator will find.

    Practice: Practice: MDSAP at a glance: the regulators and the audit · 3 questions

Part 2The audit approach, process by processApprox. 193 min

  1. The audit approach and the audit cycle14 min

    The MDSAP audit approach: processes, tasks and linkages, audit sequence, and the three-year cycle of initial, surveillance and re-audits.

    What this module covers

    Opens with two ways to audit DEF Medical: one auditor works down a list and picks a design project at random, while the other starts with measurement and improvement, finds a corrective action on alarms users could not hear, and follows it into the alarm redesign project. Explains the audit approach: processes, tasks written as the auditor meets them, and linkages and risk management that tie the processes together and guide the samples. Covers the sequence of Management, measurement and improvement, design, then production, with purchasing alongside, and the trail of records from a complaint to the release of a changed device. Then shows DEF Medical's plan for its first three-year cycle: an initial audit in two stages, two surveillance audits and a re-audit, with a hearing aid maker in Sydney. Ends with a simple test and a recap.

    What you will be able to do

    • Explain how linkages between processes guide the auditor's samples
    • Describe the MDSAP audit sequence across the seven processes
    • Plan an audit programme for the three-year MDSAP cycle

    Why it matters

    Following the trail rather than clause numbers is how MDSAP auditors find problems, so preparing the same way finds them first.

    Practice: Practice: The audit approach and the audit cycle · 3 questions

  2. Process 1: Management14 min

    MDSAP Process 1 Management: its purpose, eleven tasks, management commitment, authorised shipments and country-specific add-ons.

    What this module covers

    Starts with a situation that could happen at DEF Medical: a distributor orders twenty monitors for a market where the new model's application is still under review, and the order system accepts it. Explains why such controls sit in the Management process, which verifies that top management keeps an adequate and effective quality system. Covers its eleven tasks, from quality system planning to making sure devices ship only where they are authorised, with management commitment judged at the end. Then shows where the countries differ: Australia's Sponsor and the Australian register, Canada's importers and distributors, Brazil's rules on consultants, and longer record retention in some markets such as Japan, with a surgical instrument maker in Frankfurt that sells in Brazil and uses an outside design consultant. Ends with a simple test and a recap.

    What you will be able to do

    • Explain what the MDSAP Management process verifies
    • Check that controls stop devices shipping to markets where they are not authorised
    • Identify the country add-ons for Australia, Canada, Brazil and Japan

    Why it matters

    Management owns the controls behind every process; an order accepted for an unauthorised market is a management failure.

    Practice: Practice: Process 1: Management · 3 questions

  3. Process 2: Authorisation and registration14 min

    MDSAP Process 2: marketing authorisation and facility registration in Canada, the United States, Australia, Japan and Brazil, and change assessment.

    What this module covers

    Opens with DEF Medical improving the alarm algorithm in its patient monitor software, verified and validated through design control, then asks which regulators must be notified or asked for approval in each of its five markets. Explains who applies in each market: the manufacturer for a Canadian device licence, the owner or operator registering and listing in the United States, the Sponsor for the ARTG in Australia, a marketing authorisation holder resident in Japan, and a domestic manufacturer or importer in Brazil. Covers each market's rules for registration, listing, licences and approvals, such as registering within thirty days in the United States, registered manufacturing sites for Japan, and registration or notification by class in Brazil. Then shows how DEF Medical assesses the alarm software change for every market before release. Ends with a recap.

    What you will be able to do

    • Identify who applies for authorisation in each MDSAP market
    • Explain the registration and listing duties the auditor checks
    • Assess a design change for every market before release

    Why it matters

    Authorised first, shipped second; a change released before every market is assessed can put devices on sale unlawfully.

    Practice: Practice: Process 2: Authorisation and registration · 3 questions

  4. Practice exercise: A market and registration map for DEF Medicalabout 12 min
  5. Process 3: Measurement, analysis and improvement14 min

    MDSAP Process 3: measurement, analysis and improvement, data sources, investigations, CAPA, nonconforming product, internal audit and management review.

    What this module covers

    Returns to the Medtronic case from Module 1, where the December 2021 warning letter named risk assessment, corrective and preventive action, complaint handling, recalls and adverse event reporting, almost all of which sit in or link to this process. Explains how the auditor follows the improvement loop record by record. Covers the sources of quality data the audit approach names, connecting and analysing them with sound methods, and investigating problems in proportion to risk. Then covers corrective and preventive actions that must be shown to work, including the changes they cause, and the Japan rule on notifying significant process changes, shown in a corrective action record from DEF Medical that an auditor samples. Ends with nonconforming product before and after delivery, independent internal audits, management review input, a simple test and a recap.

    What you will be able to do

    • List the quality data sources the MDSAP audit approach names
    • Investigate problems in proportion to risk and show CAPA works
    • Check that internal audit is independent and feeds management review

    Why it matters

    Data in, causes found, problems gone; a CAPA system that shows its actions work is central to every MDSAP audit.

    Practice: Practice: Process 3: Measurement, analysis and improvement · 3 questions

  6. Complaints, adverse events and advisory notices14 min

    MDSAP complaint handling, medical device adverse event reporting and advisory notices across the five markets, with reporting timeframes.

    What this module covers

    Looks again at the Philips recall and the Medtronic warning letter, where complaints, reports and recalls behaved as one chain across many markets. Explains how complaints are handled, investigated and recorded to the rules of every market you supply, and feed risk management. Covers assessing every complaint for adverse event reporting against each market's criteria and timeframes, why reporting clocks start when you become aware, why malfunctions can be reportable, and justifying decisions not to report, with the Japan arrangements between registered site and marketing authorisation holder. Shows how DEF Medical records a reporting decision, an example of what the auditor samples. Then covers advisory notices decided by risk, scoped across markets and reported within each market's rules. Ends with keeping one table of every market's reporting timeframes built into the complaint form, and a recap.

    What you will be able to do

    • Assess each complaint for adverse event reporting in every market
    • Record and justify a decision not to report
    • Scope an advisory notice across all affected markets

    Why it matters

    One event can be reportable in one market and not another; a timeframe table on the complaint form prevents late reports.

    Practice: Practice: Complaints, adverse events and advisory notices · 3 questions

  7. Practice exercise: Is this complaint reportable, and where?about 15 min
  8. Process 5: Design and development14 min

    MDSAP Process 5 design and development: choosing the project, seventeen tasks, verification and validation, software, risk, design changes and transfer.

    What this module covers

    Returns to DEF Medical's corrective action on alarms that were hard to hear, now followed into design and development, where the auditor selects the alarm redesign project. Explains the priority criteria for choosing a design project: complaints, risk and recent changes. Covers the seventeen tasks: planning, complete inputs, verified outputs, validation of the device and its software including testing at user sites, and risk controls shown to work, with acceptance criteria set before each test and Australia's design procedure requirements. Then covers design transfer in steps and design change control for the whole life of the product, shown in DEF Medical's design change record for the alarm fix, including risks, devices already delivered and every market assessed. Ends with common myths, a simple test and a recap.

    What you will be able to do

    • Explain how the auditor chooses a design project to sample
    • Check that verification has acceptance criteria set before testing
    • Control a design change, including devices already delivered

    Why it matters

    Verified, validated and risk-checked design records are what let a design change pass through every market's review.

    Practice: Practice: Process 5: Design and development · 3 questions

  9. Process 6, part 1: validation, sterilisation14 min

    MDSAP Process 6 production and service controls, part 1: production planning, process selection, controlled conditions, process validation and sterilisation.

    What this module covers

    Opens with DEF Medical's Chicago steriliser moving the transducers to a new sterilisation chamber and mentioning it in a short e-mail, while batches keep shipping on certificates that still say pass. Explains how auditors choose production processes by corrective action signals, risk, novelty and wide use. Covers controlled conditions, including buildings, workspace, equipment and supporting services, and a clean, suitable and monitored environment. Then explains why processes such as sterilisation, welding or moulding, whose results cannot be fully verified, must be validated with criteria set first, and why every change to a validated process is reviewed and revalidated where appropriate, with outsourced processes staying your responsibility. Shows DEF Medical's sterilisation file after it dealt with the chamber change. Ends with a simple test and a recap.

    What you will be able to do

    • Explain how auditors select production processes to sample
    • Identify processes that must be validated because results cannot be fully verified
    • Review and revalidate a changed process before release

    Why it matters

    A validated process that changes without review leaves nobody able to show the product is sterile or safe.

    Practice: Practice: Process 6, part 1: validation, sterilisation · 3 questions

  10. Process 6, part 2: records, traceability14 min

    MDSAP Process 6 part 2: competence, measuring equipment, production software, the device master file, batch records, traceability and servicing.

    What this module covers

    Starts with an everyday event at DEF Medical: the torque gauge for the monitor's mounting screws is found out of tolerance at calibration, adjusted and returned to use, leaving the question of the monitors it measured since its last good calibration. Explains competent people, calibrated measuring equipment, look-back on out-of-tolerance results, and validated production software, even when you never see its code. Shows DEF Medical's look-back record for the torque gauge. Covers the device master file and batch records showing each batch was made, labelled and released as planned, and traceability set by risk, full for implants and life-supporting devices. Then covers distribution, installation and service records as quality data that close the loop. Ends with a simple test, a recap and a practice exercise to plan an audit trail through one batch.

    What you will be able to do

    • Carry out a look-back after an out-of-tolerance calibration
    • Check that batch records show each batch was made and released as planned
    • Set the extent of traceability by risk

    Why it matters

    One batch traced both ways is how you limit a recall to the devices actually affected.

    Practice: Practice: Process 6, part 2: records, traceability · 3 questions

  11. Practice exercise: An audit trail from a batch record to a supplierabout 15 min
  12. Process 7: Purchasing13 min

    MDSAP Process 7 purchasing: supplier selection, controls by risk, written agreements on change notification, monitoring and incoming verification.

    What this module covers

    Opens with DEF Medical's Singapore circuit board maker switching to a cheaper capacitor of the same rating without telling DEF Medical, followed months later by complaints of monitors resetting in hot rooms. Explains that a supplier is anyone outside your quality system who supplies what you use, including companies in your own group, contractors and consultants. Covers control that grows with the effect on the device: selection on capability, written agreements that require notification of changes, real monitoring and re-evaluation that follows the product's significance and the supplier's performance. Then covers verification of what arrives, which must be able to catch the faults that matter, and the Australian Sponsor duties not audited at the manufacturer. Shows DEF Medical's supplier file for the Singapore board maker after the capacitor problem. Ends with myths, a simple test and a recap.

    What you will be able to do

    • Set supplier controls in proportion to the effect on the device
    • Write a supplier agreement that requires notice of changes
    • Design incoming checks able to catch the faults that matter

    Why it matters

    An unnotified supplier change can reach patients months later; risk-based controls catch it at the agreement or the gate.

    Practice: Practice: Process 7: Purchasing · 3 questions

  13. Grading nonconformities and the timeline13 min

    MDSAP nonconformity grading from one to five, the grading and exchange form, five-day notices and the post-audit timeline for remediation.

    What this module covers

    Starts with two findings an auditor might raise at DEF Medical: a skipped procedure step with no product affected, and faulty monitors shipped to hospitals for a second audit in a row, and why regulators need to see at once which is worse. Explains how a nonconformity names the requirement, states the failure and gives traceable evidence, recorded on a grading and exchange form that travels with the audit report. Covers grading: starting at grade one or three by clause, and escalating for a repeat, a missing and unimplemented process, or a released nonconforming device, up to five, with no overall grade. Then shows the rules on four findings at DEF Medical, and the timeline from day zero: a possible five-day notice, a remediation plan in fifteen days, and evidence for grades four and five in thirty. Ends with an exercise and a recap.

    What you will be able to do

    • Write a nonconformity with requirement, failure and evidence
    • Grade a nonconformity from one to five using the escalation rules
    • Meet the post-audit timeline for remediation plans and evidence

    Why it matters

    Fixing the cause before the next audit avoids repeat findings, which escalate grades and can trigger a five-day notice.

    Practice: Practice: Grading nonconformities and the timeline · 3 questions

  14. Practice exercise: Write and grade four MDSAP nonconformitiesabout 15 min

Part 3A mock MDSAP audit and your road mapApprox. 12 min

  1. Putting it together: a mock MDSAP audit12 min

    A mock MDSAP audit at DEF Medical through all seven processes, graded findings, a readiness road map, a checklist and the final exam.

    What this module covers

    Begins with the end of the Philips story from Module 1: an April 2024 consent decree after the June 2021 recall. Then walks through a mock MDSAP audit at DEF Medical in the audit approach's own sequence, following the plan from Module 3. On day one the auditor starts with Management and finds a recent change in Brazilian rules not identified, then follows trails through the other processes, finding issues such as distribution records with missing details. Shows how the findings are graded and DEF Medical's remediation plan for a grade three reporting finding, sent within fifteen days, with its cause and corrective action. Gives a readiness road map: fix your scope, assess gaps process by process, close them, audit yourself in MDSAP order, then contract a recognised auditing organisation, plus a checklist. Ends with the final exam: 60% to succeed, one retake included.

    What you will be able to do

    • Follow audit trails through all seven MDSAP processes
    • Write a remediation plan with cause and corrective action
    • Apply the five-step readiness road map to your own organisation

    Why it matters

    Rehearsing a full MDSAP audit shows where your trails break and gives you a plan to fix them before the real one.

    Practice: Practice: Putting it together: a mock MDSAP audit · 3 questions

Frequently asked questions

Your questions,
answered.

About MDSAP: Medical Device Single Audit Program Training, its certificate and enrolment.

Ask Sterling
Is Sterling Academy a good choice for MDSAP training?

Yes. Sterling Academy's MDSAP training is built by the Sterling consulting group, which has taken organisations to certification across 8,100+ client engagements in 60+ countries over 20+ years. It is always on the current edition, with practice questions that show the right answer. Each course ends with a final exam and a verifiable certificate that anyone can check online, plus a LinkedIn badge, and client administrators can show an auditor exactly who has been trained. You will be able to apply MDSAP: Medical Device Single Audit Program at work and show your competence with confidence. Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.

What is MDSAP training?

MDSAP training explains how the Medical Device Single Audit Program audits a device manufacturer. This course covers the audit approach and its processes, ISO 13485:2016 and the added requirements of the US, Canada, Australia, Brazil and Japan, adverse event reporting, nonconformity grading and the post-audit timeline, using a built patient monitor maker in Toronto.

Who needs MDSAP training?

Device manufacturers preparing for or holding MDSAP certification need it. It suits quality and regulatory affairs managers, QMS leads preparing a first audit, internal auditors of device quality systems, and engineers whose design, production or supplier processes are audited, as well as consultants supporting MDSAP readiness.

Is MDSAP mandatory?

MDSAP is mandatory in practice for Canada: Health Canada has accepted only MDSAP certificates since 1 January 2019. The other participating regulators use MDSAP audit reports in different ways; for example, the US FDA may accept them as a substitute for routine inspections. Module 2 explains how each regulator uses the audit.

What is the difference between ISO 13485 and MDSAP?

ISO 13485:2016 is the quality management standard; MDSAP is an audit programme that checks it together with five regulators' requirements. An MDSAP audit adds jurisdiction-specific topics such as marketing authorisation, facility registration and adverse event reporting, and grades nonconformities on a five-level scale.

How long does the MDSAP course take?

The course has about 3 hours of video across 13 modules, plus four practice exercises of 12 to 15 minutes each. It is on demand, so you can work through it module by module around audit preparation and replay any part when you need it.

How are MDSAP nonconformities graded?

They are graded from 1 to 5 in two steps. First the auditor decides whether the finding has an indirect or direct impact on the quality system, then escalation rules can raise the grade, for example for repeat findings. Module 12 teaches the method and the five-day notice and post-audit timelines.

Do I get a certificate?

Yes, you receive a Sterling Academy Certificate of Competence. The course ends with a scenario-based multiple-choice exam drawn from the question bank; a score of 60% or more meets the criteria, and one retake is included. The certificate records your training.

How much does MDSAP training cost?

The course costs US$99 per learner, including all 13 video modules, practice questions, four practice exercises with model answers, the final exam and the certificate. For teams, contact us for a quote for your organisation; company plans include a client administrator, progress reports and one invoice.

Is the course up to date with the 2026 audit approach?

Yes, it is aligned with the February 2026 version 010 of the audit approach. The modules teach the structure, sequence and tasks of version 009, which version 010 kept, and state where version 010 changed a point, such as supplier wording and US references to the QMSR.

Does the course cover software and sterilisation?

Yes, both are covered where the audit approach covers them. Module 8 includes software in design and development, and Module 9 covers process validation and sterilisation, using DEF Medical's monitor software and its ethylene oxide sterilised transducers as examples. Module 10 adds software used in production and the device file.

Can my team take MDSAP training together?

Yes, through a Sterling Academy company plan. A client administrator adds your quality, regulatory and engineering staff, assigns the course, and follows progress reports, and your organisation receives one invoice. Contact us for a quote for your organisation based on the number of learners and courses you need.

Your certificate

Prove what you learned.
Share it with confidence.

You will be able to apply MDSAP: Medical Device Single Audit Program at work and show your competence with confidence. Your certificate can be verified online in seconds, so certification body auditors, employers and clients can confirm your training instantly.

Complete the course and its final exam and you receive a Sterling Academy Certificate of Completion, verifiable online by QR code, with a LinkedIn badge to share.

Pass mark
70%
Prerequisites
None

Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.

Ask about course requirements

Your next step

Get consulting from Sterling

Expert and experienced consultants, 8,100+ client engagements in 60+ countries, from gap assessment to a system ready for its certification audit.

Talk to a Sterling consultant

Not sure which course?

Plan your next step
in learning.

Discuss your learning needs