Practitioner training · Medical device quality

Design controls training for medical devices: ISO 13485:2016 and the FDA QMSR

Part of the ISO 13485:2016 learning path → Step 2

If you run a device development project, preparing for an FDA inspection or a notified body audit, or have just inherited a design and development file with gaps, this design controls training shows you how to run design controls that produce a safe device and records that stand up to inspection. You will know what a verifiable design input looks like, how to justify a sample size, and when a change needs revalidation.

The course covers ISO 13485:2016 clause 7.3 as the FDA Quality Management System Regulation (QMSR) has applied it since 2 February 2026: the plan, inputs, outputs, reviews, verification, validation including usability, transfer, changes and the design and development file, linked to risk management under ISO 14971. PQR Health, a San Francisco company developing a wearable continuous glucose monitor with a phone app, runs through the course.

Design controls training teaches medical device teams how to control design and development under ISO 13485:2016 clause 7.3 and the FDA QMSR: planning, user needs and design inputs, outputs, design reviews, traceability, verification, validation and usability, design transfer, design changes and the design and development file, with risk management integrated throughout.

Training a team? Get a quote for your organisation

Part of: Medical Device Quality and Risk Management Training

Part of: GMP & Medical Devices

Secure payment by Stripe · for yourself or for your team

What you get

  • 13 video modules

    About 3 hours, with captions. Watch at your own pace on any device.

  • Practice after every module

    Short questions check your understanding before you move on.

  • Final exam

    Multiple choice, with immediate retakes if you need them.

  • Built by experts

    Industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC.

A certificate you can prove, and share

Verifiable certificate with a QR code anyone can scan, plus a digital badge to add to your LinkedIn profile.

See how verification works →

Standard and editionISO 13485:2016 design and development, as incorporated in 21 CFR Part 820 (QMSR)

Last updated31 October 2026

Why design controls training matters now

A device is only as safe as its design, and FDA warning letters keep finding the same design control gaps, from established manufacturers to small companies.

In March 2025, FDA issued a warning letter to Dexcom, maker of the G6 and G7 continuous glucose monitors. Among the findings: design inputs did not clearly define all the special control requirements for the device type, a significant change to a sensor component was not adequately evaluated and validated, with clinical study primary endpoints not met, and hazard analyses did not address use with automated insulin dosing systems.

In August 2026, FDA wrote to Pensar Medical, a maker of negative pressure wound therapy systems, after finding eleven software changes approved and closed without records that they had been correctly and safely implemented, including a change described as "clean up all code" with no verification record, and a software validation procedure that did not address regression testing.

Since 2 February 2026, the QMSR has applied ISO 13485 clause 7.3 to most devices sold in the US, so these expectations now sit on the same text that certification bodies audit worldwide.

Who this design controls training course is for

It is for anyone who designs, documents or approves medical device development for the United States, Europe and other regulated markets.

  • R&D and design engineers writing inputs, outputs and test protocols
  • Project managers running device development projects
  • Quality and regulatory affairs staff who review design files and face audits and inspections
  • Software and systems engineers on connected devices and device software
  • Start-up founders setting up design controls for a first product
  • Teams with an inspection finding or audit nonconformity against design controls

What you will learn

Every outcome is practised on PQR Health's glucose monitor, with documents filled in as the project moves from plan to launch.

  • Plan design and development with stages, reviews and responsibilities
  • Write design inputs that are complete, unambiguous and verifiable
  • Produce design outputs and keep traceability from needs to tests
  • Plan and run design verification and design validation, including usability
  • Control design transfer and design changes
  • Build a design and development file ready for audit and inspection

Course outline: 13 modules

Each topic follows seven steps: a real situation, the requirement with its clause on screen, a plain explanation, how PQR Health applies it, the evidence, the common mistake, and how to check it is working.

  • Module 1, Welcome: why design controls matter: three recent cases, PQR Health, what design controls are, and the scope.
  • Module 2, Design controls at a glance: who must apply design controls, the parts of clause 7.3, what changed and the links to risk.
  • Module 3, The design and development plan: what a design plan documents, stages and reviews, roles, traceability and resources.
  • Module 4, User needs and design inputs: intended use, users and use environments, user needs, foreseeable misuse and the first inputs.
  • Module 5, Writing verifiable design inputs: the qualities of a good input, a pattern to write one, and regulations and standards as inputs.
  • Module 6, Design outputs and acceptance criteria: what outputs must do, acceptance criteria, essential characteristics and approval.
  • Module 7, Design reviews and traceability: who takes part, independent reviewers, the review record and the traceability matrix.
  • Module 8, Design verification and sample sizes: verification plans, test methods, sample-size rationale, connected devices and records.
  • Module 9, Design validation and usability: representative product, clinical evaluation and human factors validation testing.
  • Module 10, Design transfer and design changes: transfer to production, change control, significance and effect on delivered product.
  • Module 11, The design file and the medical device file: the design and development file, the medical device file, the former DHF and DMR.
  • Module 12, Software, connected devices and risk: software changes and regression, risk through design, connected systems and cybersecurity.
  • Module 13, Putting it together: findings and the exam: common findings, a worked pre-launch design review, a checklist and a road map.

Design control requirements explained: ISO 13485:2016 and the QMSR

ISO 13485:2016 sets quality management system requirements for organisations involved in medical devices, whatever their size. Clause 7.3, design and development, runs from 7.3.1 to 7.3.10, covering planning, inputs, outputs, review, verification, validation, transfer, control of changes and the design and development file, with records throughout. Clause 7.1 requires risk management throughout product realisation, which the course connects to ISO 14971, and clause 7.3.3 names usability among the inputs.

In the US, the Quality Management System Regulation, 21 CFR Part 820, took effect on 2 February 2026. It incorporates ISO 13485 by reference and applies clause 7.3 to class II and class III devices and to certain class I devices, including those automated with software. The former design control section, 820.30, and the design history file have given way to the ISO 13485 terms; the course shows how the old and new records map, which matters when an older warning letter cites 820.30.

For connected devices and device software, the course also draws on FDA's human factors guidance and names its current guidance on software submissions and on cybersecurity, so that usability, software changes and cybersecurity are treated as design inputs and controlled through change.

How the course works

The course is 13 on-demand video modules, about 3 hours of video in total. You learn online, on any device, at your own pace. Three practice questions follow each module, and four practice exercises with model answers let you produce real design documents: a design plan for the next project, five vague design inputs rewritten as verifiable ones, a verification plan with sample sizes, and a design change record for a software change.

The final exam is a scenario-based multiple-choice exam drawn from the course's question bank. Score 60% or more for the Sterling Academy Certificate of Competence; one retake is included. Compliance is shown by your design records.

What you can do after the course

On your current project, you can put the course to work at once.

  • Write or repair a design and development plan with stages, reviews, responsibilities and traceability
  • Turn user needs into design inputs that are complete, unambiguous and verifiable, including regulatory requirements
  • Build a traceability matrix from user needs to inputs, outputs, verification and validation
  • Justify verification sample sizes and plan human factors validation testing
  • Decide whether a design change is significant and what verification, validation and risk review it needs
  • Assemble a design and development file an auditor or FDA investigator can follow

For teams and organisations

Design controls work when engineering, software, quality and regulatory staff share one method. With a company plan, a client administrator adds your team, assigns the course and follows progress in reports, with one invoice. Training a team? Get a quote for your organisation.

Why Sterling Academy

Sterling Academy courses are built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC. The Academy is the training arm of Sterling International Consulting, with 8,100+ client engagements in 60+ countries over 20+ years. Every course teaches the current texts: here, ISO 13485:2016 and the FDA QMSR in force since 2 February 2026.

Preview this course

Experience the learning
before you enrol.

Watch a sample from Design Controls for Medical Devices before you enrol.

Design Controls for Medical DevicesSample

Inside the course

A clear path through the essentials.

13 modules, 13 practice checkpoints, 4 practice exercises and a final exam. Video runtimes are approximate; allow additional time for the practice questions and the final exam. Modules marked optional can be skipped; the others are studied in any order.

Part 1Foundations and design controls at a glanceApprox. 27 min

  1. Welcome: why design controls matter12 min

    Design controls for medical devices: three recent FDA warning letters on inputs, changes and software, the device we follow and how the course works.

    What this module covers

    Opens with a self-check: what is a design input, how does it differ from a user need, and who decides a design is ready for production? Presents three recent FDA cases: the March 2025 warning letter to Dexcom on design inputs, an inadequately evaluated sensor component change and hazard analyses that missed automated insulin dosing; a July 2026 letter to Koven Technologies, whose manual added fetal heart sounds as a use with no design change records; and an August 2026 letter to Pensar Medical, a maker of wound therapy systems, about software changes. Shows design controls in one picture, as set out in clause 7.3 of ISO 13485 and applied by FDA's QMSR. Introduces PQR Health Inc. in San Francisco, designing a wearable continuous glucose monitor with sensors from a contract manufacturer in Singapore. Ends with the thirteen modules, practice exercises and exam, and a recap.

    What you will be able to do

    • Explain what recent FDA warning letters reveal about design control failures
    • Describe design controls under clause 7.3 of ISO 13485 in one picture
    • State why changing a device's intended use is a design change

    Why it matters

    Seeing what FDA cited at real device makers shows which design records an inspector will ask for at your company.

    Practice: Practice: Welcome: why design controls matter · 3 questions

  2. Design controls at a glance15 min

    Design controls at a glance: who must comply under the FDA QMSR and ISO 13485 clause 7.3, the ten parts, verification versus validation, and risk links.

    What this module covers

    Starts with a choice every start-up faces, told at PQR Health: building prototypes fast and adding design controls after the clinical study, then spending months rebuilding records, versus starting design controls when design starts. Explains who must apply design controls in the United States: since 2 February 2026, section 820.10(c) of the QMSR requires clause 7.3 of ISO 13485 for class two and three devices, class one devices with software and five listed class one types, including devices used in clinical investigations. Covers the ten parts of clause 7.3, from the plan to the design and development file, and how verification asks did we build it right while validation asks did we build the right thing. Shows the outline of PQR Health's design control procedure and how risk management and usability connect to every part. Ends with a simple test and a recap.

    What you will be able to do

    • Identify which devices must comply with design controls under the QMSR
    • List the ten parts of clause 7.3 in order
    • Explain the difference between design verification and design validation

    Why it matters

    Starting design controls when design starts avoids months of rebuilding requirements and test records before a submission.

    Practice: Practice: Design controls at a glance · 3 questions

Part 2Design controls, step by stepApprox. 197 min

  1. The design and development plan14 min

    The design and development plan under ISO 13485 clause 7.3.2: design stages, design reviews, verification, validation, transfer, traceability and resources.

    What this module covers

    Opens with two versions of PQR Health's first design plan: a schedule written at kick-off and never updated, which loses six months when validation needs production sensors that do not exist, and a plan that names stages, reviews and owners. Explains clause 7.3.2, which asks the plan to document stages, reviews, verification, validation and transfer activities, responsibilities, traceability methods and resources. Shows the stages in PQR Health's plan, from a feasibility bench study of accuracy through verification of each design input, the clinical study and human factors validation test, to validation of sensor manufacturing processes at the contract manufacturer. Covers why stages are your choice, each ending in a documented design review, and how plan size varies, with a hip implant system at a maker in Chicago. Ends with keeping the plan current, a recap and a practice exercise writing a design plan.

    What you will be able to do

    • Write a design plan covering the six items of clause 7.3.2
    • Choose design stages that each end in a documented review
    • Keep the plan updated through controlled revisions

    Why it matters

    A plan the team actually uses, kept current, spots problems like missing production sensors months before validation.

    Practice: Practice: The design and development plan · 3 questions

  2. Practice exercise: A design plan for the next projectabout 15 min
  3. User needs and design inputs14 min

    User needs, intended use, use environments and design inputs: ISO 13485 clauses 7.2.1 and 7.3.3 and FDA human factors guidance.

    What this module covers

    Starts with a design decision at PQR Health: how to warn a user of dangerously low glucose. One team imagines a user awake with the phone's sound on, and night-time alerts go unnoticed; the other studies real users first. Explains that the intended use comes first, described by six elements, and that clause 7.2.1 asks for stated and unstated requirements, regulatory requirements and training. Covers studying and documenting real users and use environments, including foreseeable misuse, as FDA's human factors guidance recommends. Then shows how PQR Health turns one need into inputs, with four examples of the record a company keeps, and how clause 7.3.3 turns needs, risk outputs and regulatory requirements into recorded, approved design inputs, each traced to its source. Ends with a simple test and a recap.

    What you will be able to do

    • Describe the intended use using its six elements
    • Document real users, use environments and foreseeable misuse
    • Turn a user need into design inputs traced to their source

    Why it matters

    Designing for the user you actually have prevents alerts that go unheard at night and failures found late in testing.

    Practice: Practice: User needs and design inputs · 3 questions

  4. Writing verifiable design inputs14 min

    Writing verifiable design inputs under ISO 13485 clause 7.3.3: value, conditions, method and source, regulatory requirements and FDA special controls.

    What this module covers

    Returns to the March 2025 warning letter to a glucose monitor maker, where design inputs did not clearly define the special controls for integrated continuous glucose monitors under section 862.1355 of FDA's rules. Explains clause 7.3.3: inputs that are complete, unambiguous, able to be verified or validated, not in conflict, reviewed and approved. Shows the simple pattern PQR Health uses, a value, the conditions, a method and the source, with four inputs before and after rewriting, and a surgical stapler maker in Los Angeles rewriting the staple line shall be strong. Covers how regulatory requirements and standards become precisely quoted inputs, with three of the rule's accuracy requirements for adults. Then shows a conflict PQR Health found between inputs and the check it runs on its input list. Ends with a recap.

    What you will be able to do

    • Write a design input with a value, conditions, method and source
    • Turn a regulatory requirement into precisely quoted inputs
    • Find and resolve conflicts between design inputs

    Why it matters

    An input is finished when its test is clear; vague inputs are what FDA cited when special controls were not defined.

    Practice: Practice: Writing verifiable design inputs · 3 questions

  5. Practice exercise: Rewrite five vague design inputsabout 12 min
  6. Design outputs and acceptance criteria14 min

    Design outputs under ISO 13485 clause 7.3.4: meeting inputs, acceptance criteria, essential characteristics, approval and the link to production.

    What this module covers

    Starts with another finding from the March 2025 letter: sensors accepted on the average coating thickness across a sample, with no criteria for individual sensors. Explains clause 7.3.4: outputs that meet inputs, inform purchasing and production, contain acceptance criteria, specify essential characteristics, are in a form suitable for verification and are approved before release. Shows how essential characteristics move from the risk file into the design, and how outputs speak the same language as inputs, with PQR Health's software specification stating alert timing and referencing DI-031. Covers part of PQR Health's output list, where outputs go and how they stay under control, with a hip implant maker in Chicago marking joint surface finish as an essential characteristic. Ends with the final design output starting the medical device file, and a recap.

    What you will be able to do

    • Write acceptance criteria that fit how the device can fail
    • Identify essential characteristics from the risk file
    • Check that each output can be verified against its input

    Why it matters

    Acceptance criteria based on averages can pass faulty units; criteria that fit how the device fails protect every patient.

    Practice: Practice: Design outputs and acceptance criteria · 3 questions

  7. Design reviews and traceability14 min

    Medical device design reviews under clause 7.3.5: participants, review packages, records, and the design traceability matrix from needs to tests.

    What this module covers

    Opens with two versions of the review closing PQR Health's development stage: progress slides that miss an unverified alert sound level with the phone on silent, and a review that walks the traceability matrix input by input. Explains clause 7.3.5: systematic reviews at suitable stages that evaluate results, propose actions and are recorded with the design, participants and date. Covers participants, including the functions concerned, the contract manufacturer in Singapore and other specialists, and why an independent reviewer, though no longer named, remains good practice. Shows how to prepare a review package a week ahead and PQR Health's record for its development stage review. Then builds the traceability matrix linking needs, inputs, outputs, risk controls and tests, and shows how it lets a change review list every test to repeat in minutes. Ends with a recap.

    What you will be able to do

    • Run a design review that evaluates results and records decisions
    • Prepare a review package with matrix, test results and risk file
    • Build a traceability matrix from user needs to tests

    Why it matters

    Reviews that decide and links that hold catch gaps at the review table instead of in the clinical study months later.

    Practice: Practice: Design reviews and traceability · 3 questions

  8. Design verification and sample sizes14 min

    Medical device design verification under clause 7.3.6: verification plans, test method validation, measurement uncertainty, sample size rationale and records.

    What this module covers

    Starts with a test method finding from the March 2025 letter: a key method validated by recording only pass or fail rather than measured values, which FDA said could not show repeatable or reproducible results. Explains clause 7.3.6: documented verification plans with methods, acceptance criteria and a rationale for sample size, and records of results and conclusions. Shows part of PQR Health's verification plan, then covers validated test methods, recorded measured values, calibrated equipment and measurement uncertainty. Covers verifying connected devices as connected, sample sizes that follow the risk, with one simple, widely used calculation, and a hip implant maker in Chicago fatigue-testing implants for millions of cycles. Ends with reports filed in the design file and linked to the matrix, every input closed with measured data, a recap and a practice exercise writing a verification plan.

    What you will be able to do

    • Write a verification plan with methods, criteria and sample size rationale
    • Validate a test method using measured values, not pass or fail
    • Choose a sample size that follows the risk and record why

    Why it matters

    Verify the test, then trust the result; an unvalidated method makes every result built on it open to challenge.

    Practice: Practice: Design verification and sample sizes · 3 questions

  9. Practice exercise: A verification plan with sample sizesabout 15 min
  10. Design validation and usability14 min

    Design validation under ISO 13485 clause 7.3.7: representative product, clinical evaluation and FDA human factors (usability) validation testing.

    What this module covers

    Opens with the March 2025 finding that hazard analyses for the G6 and G7 monitors did not address use with automated insulin dosing systems, cited as a design validation failure. Explains clause 7.3.7: planned validation on representative product, including when connected, completed before release, with records. Covers clinical or performance evaluation under the regulations that apply, which for PQR Health's monitor are specific, including data for children or an accepted justification. Then covers the human factors validation test FDA expects: every critical task, representative users, generally at least 15 participants per group reflecting differences such as age, literacy and dexterity, and the final design, with design fixes before instruction fixes. Shows how PQR Health applies this, a situation from its usability study, and an inhaler maker in London. Ends with a simple test and a recap.

    What you will be able to do

    • Plan design validation on representative, connected product
    • Explain the clinical evaluation needed for the device
    • Plan a human factors validation test for every critical task

    Why it matters

    Real users, final design and real conditions find use errors that bench testing never shows.

    Practice: Practice: Design validation and usability · 3 questions

  11. Design transfer and design changes14 min

    Design transfer under ISO 13485 clause 7.3.8 and design changes under clause 7.3.9: significance, impact review, verification and approval.

    What this module covers

    Starts with one more finding from the March 2025 letter: a significant change to a sensor resistance layer component whose equivalence study did not meet its primary endpoints, yet commercial manufacturing continued. Explains clause 7.3.8: transfer procedures that confirm outputs are suitable for manufacturing and production can meet requirements, with results recorded, shown in part of PQR Health's transfer checklist. Covers clause 7.3.9: identifying each change, judging its significance, and reviewing its effect on parts, product in process and product already delivered, risk management and processes, then verifying, validating and approving before implementation, using the traceability matrix to pick the tests to repeat. Shows a filled change record at PQR Health and a dental implant maker in Mumbai moving machining to a new site. Ends with a recap and a practice exercise writing a software change record.

    What you will be able to do

    • Confirm through transfer that production can meet the design
    • Judge the significance of a design change and review its impact
    • Write a design change record from significance to approval

    Why it matters

    No change reaches a patient unreviewed; judging significance properly stops a worse-performing component reaching the market.

    Practice: Practice: Design transfer and design changes · 3 questions

  12. Practice exercise: A design change record for a software changeabout 15 min
  13. The design file and the medical device file14 min

    The design and development file (ISO 13485 clause 7.3.10) and the medical device file (clause 4.2.3), replacing the old US record names.

    What this module covers

    Opens with a July 2026 warning letter to a maker of dialysis concentrates whose procedure and quality manual described every design step, yet it could not produce records showing its six marketed devices were developed under the clause. Explains clause 7.3.10: a design and development file for each device type or family, containing or referencing the design and change records, shown in PQR Health's design file index. Covers clause 4.2.3 and the medical device file, the current recipe, which now holds what the former device master record held, and what happened to the old US record names. Then covers the rules for records: legible, retrievable and secure, with changes visible and gaps fixed honestly, never by backdating, with a surgical stapler maker in Paris keeping one file for a family of six sizes. Ends with a simple test and a recap.

    What you will be able to do

    • Build a design and development file index for a device family
    • Explain what the medical device file holds under clause 4.2.3
    • Fix gaps in design records honestly, without backdating

    Why it matters

    If it is not in the file, it did not happen; a complete design file is what lets you answer an inspector in minutes.

    Practice: Practice: The design file and the medical device file · 3 questions

  14. Software, connected devices and risk14 min

    Medical device software changes, risk management throughout design (ISO 13485 clause 7.1), connected devices and cybersecurity.

    What this module covers

    Starts with an August 2026 warning letter to a maker of wound therapy pumps, where a firmware change described as clean up all code had no verification record and nobody could explain what changed. Explains that every software change needs a record of what changed, an impact analysis, regression checks and approval before release. Covers clause 7.1 on documented risk management in product realisation, running through inputs, outputs, verification, validation and change, with controls following the order of priority and the danger of controls left in progress. Shows PQR Health's risk control register and how it handles a third-party library update, with an insulin dose calculator app maker in Los Angeles. Then covers connected devices verified and validated as a system and security designed in from the start. Ends with two quick checks, including filtering the register for open controls, and a recap.

    What you will be able to do

    • Record and analyse the impact of every software change
    • Apply risk management through every stage of design
    • Check the risk control register for controls not yet closed

    Why it matters

    Know every version and close every control; an unexplained firmware change is exactly what FDA cited at a pump maker.

    Practice: Practice: Software, connected devices and risk · 3 questions

Part 3Putting it together, and the examApprox. 14 min

  1. Putting it together findings and the exam14 min

    Putting design controls together: common FDA findings, a worked design review at PQR Health, a ten-question checklist, a road map and the final exam.

    What this module covers

    Starts with what FDA treats as the minimum design elements in baseline inspections, following clause 7.3 of ISO 13485, with risk management running through all of them. Brings back the warning letters from the course and the pattern they share: procedures existed, but the work, the records or the timing fell short. Then walks through a worked design review at PQR Health, checking the plan, tracing a sample of user needs through inputs, outputs, verification and validation in the matrix, filtering the risk control register for anything not done, reviewing changes and the file, and shows what the review found. Gives a ten-question checklist in two parts and a road map that fixes what could affect patients first, with an owner and a date for every action. Ends with a recap and the final exam.

    What you will be able to do

    • Recognise the common pattern behind design control warning letters
    • Run a design review that traces user needs to verification and validation
    • Use the ten-question checklist on your own projects

    Why it matters

    Seeing a full design review shows exactly how an inspector tests your design records, and where to start fixing gaps.

    Practice: Practice: Putting it together findings and the exam · 3 questions

Frequently asked questions

Your questions,
answered.

About Design Controls for Medical Devices, its certificate and enrolment.

Ask Sterling
Is Sterling Academy a good choice for ISO 13485 training?

Yes. Sterling Academy's ISO 13485 courses are built by the Sterling consulting group, which has taken organisations to certification across 8,100+ client engagements in 60+ countries over 20+ years. They cover the awareness, implementation, internal auditor and specialist levels, always on the current edition, with practice questions that show the right answer. Each course ends with a final exam and a verifiable certificate that anyone can check online, plus a LinkedIn badge, and client administrators can show an auditor exactly who has been trained. You will be able to apply Design Controls for Medical Devices at work and show your competence with confidence. Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.

What is design controls training?

Design controls training teaches medical device teams how to control design and development so the device is safe and effective and the records stand up to inspection. This course covers ISO 13485:2016 clause 7.3 and the FDA QMSR, from planning and inputs to verification, validation, transfer, changes and the design file.

Are design controls mandatory for medical devices?

Yes, for most devices. ISO 13485 clause 7.3 requires them, and the FDA QMSR applies clause 7.3 to class II and III devices and certain class I devices, including those automated with software, since 2 February 2026. FDA states that investigational devices are not exempt from design controls.

What changed for design controls under the FDA QMSR?

The QMSR replaced the former Quality System regulation on 2 February 2026 and incorporates ISO 13485 by reference. Design controls now follow clause 7.3 instead of the former 820.30, and the design history file is replaced by the design and development file. Module 2 explains what changed and what stayed the same.

What is the difference between design verification and design validation?

Design verification confirms that design outputs meet design inputs, while design validation confirms that the device meets user needs and intended use. Verification asks whether you built it right; validation asks whether you built the right device, using representative product, clinical evaluation and human factors testing. Modules 8 and 9 cover both.

How long does the design controls training course take?

The course is about 3 hours of video in 13 modules, plus four practice exercises with model answers. You learn online, on any device, at your own pace. Each module ends with three practice questions, and the final exam follows Module 13.

Does the course cover software and connected devices?

Yes, Module 12 is dedicated to them. It covers software changes and regression testing, risk management through design, connected systems such as glucose monitors linked to insulin dosing systems, and cybersecurity as a design input, using the recent warning letters as examples.

Who needs design controls training?

R&D and design engineers, project managers, quality and regulatory affairs staff, software and systems engineers, and start-up founders developing medical devices for the US, Europe and other regulated markets need it. Learners new to ISO 13485 may start with the ISO 13485 awareness course.

Do I get a certificate?

Yes, you receive the Sterling Academy Certificate of Competence when you score 60% or more in the scenario-based multiple-choice final exam. One retake is included. The certificate records your training.

How much does design controls training cost?

The course costs US$99 per learner. That covers all 13 video modules, the practice questions, the four practice exercises with model answers, the final exam with one retake and the Certificate of Competence. For a development team, contact us for a quote for your organisation.

Can my development team take the training course together?

Yes, through a company plan. A client administrator adds engineers, software, quality and regulatory staff, assigns the course and follows each person's progress in reports, with one invoice. It helps a project team agree one way of writing inputs, reviews and changes. Contact us for a quote for your organisation.

Your certificate

Prove what you learned.
Share it with confidence.

You will be able to apply Design Controls for Medical Devices at work and show your competence with confidence. Your certificate can be verified online in seconds, so certification body auditors, employers and clients can confirm your training instantly.

Complete the course and its final exam and you receive a Sterling Academy Certificate of Completion, verifiable online by QR code, with a LinkedIn badge to share.

Pass mark
70%
Prerequisites
None

Sterling Academy courses carry the same content as Sterling's classroom training, whose certificates are trusted and accepted by all major certification bodies, as evidence of training at client audits for over 20 years.

Ask about course requirements

Your next step

Get consulting from Sterling

Expert and experienced consultants, 8,100+ client engagements in 60+ countries, from gap assessment to a system ready for its certification audit.