Practitioner training · Laboratory competence

Method Validation and Verification (ISO/IEC 17025:2017) Training

Online training to show, with records an assessor accepts, that each method is fit for its purpose.

ISO/IEC 17025:2017
16video modules
3.5 hourstotal learning
12 monthsaccess, any device
Final examand certificate

Built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC. 8,100+ client engagements in 60+ countries.

16modules, about 110 minutes of video
16practice checkpoints
70%pass mark, final exam
Englishwith captions

What you will be able to do

What will you learn in Method Validation and Verification (ISO/IEC 17025:2017)?

Method Validation and Verification (ISO/IEC 17025:2017) is a practitioner course for analysts, calibration technicians and technical and quality managers. Learners decide when to verify and when to validate, plan studies with fitness-for-purpose criteria, evaluate performance characteristics and write reports an assessor can follow. Online and self-paced, the training finishes with a final exam and a verifiable certificate.

It covers the selection, verification and validation of methods that ISO/IEC 17025:2017 requires of laboratories.

The training is a practitioner course on method validation and verification under ISO/IEC 17025:2017: when to verify and when to validate, planning a study, the performance characteristics from selectivity to robustness, the validation report, and keeping a method valid in routine use.

  • Decide whether a method needs verification or validation
  • Plan a validation study with fitness-for-purpose criteria set in advance
  • Evaluate selectivity, working range, linearity, limits of detection and quantification, trueness, precision and robustness
  • Write a validation record and report that an assessor can follow
  • Keep a method valid through quality control, proficiency testing and change

Part of: Laboratory Quality and Competence Training

How the course works

Five stages, from the standard to the work itself.

Every Sterling Academy course takes you through the same stages, so you leave with a skill, not just a summary.

  1. UnderstandWhy each requirement exists, in plain business language.
  2. See it doneReal workplace situations, the way our experts meet them with clients.
  3. Practise16 practice checkpoints along the way.
  4. ProveA final exam and a QR-verifiable certificate.
  5. ApplyPut the method to work in your own organisation, with what you practised in the course.

What you get

  • 16 video modules

    About 111 minutes, with captions. Watch at your own pace on any device.

  • Practice after every module

    Short questions check your understanding before you move on.

  • Final exam

    Multiple choice; retakes are unlimited and included in the price.

  • Built by experts

    Industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC.

Preview this course

Experience the learning
before you enrol.

Watch a sample from Method Validation and Verification (ISO/IEC 17025:2017) before you enrol.

Method Validation and Verification (ISO/IEC 17025:2017)Sample

Inside the course

How long does it take, and how does the course work?

16 modules, 16 practice checkpoints and a final exam. Video runtimes are approximate; allow additional time for the practice questions and the final exam.

Part 1Deciding and planningApprox. 22 min
  1. Why fit-for-purpose methods matter7 min

    Shows what it costs a laboratory when it cannot prove a method works, what fit for purpose means and the Cebu rice cadmium case followed through the course.

    What this module covers

    Opens with a Brisbane lab whose soil metals method had a spreadsheet of numbers but no plan or criteria. Gives three costs of an unproven method: an assessment finding, a customer complaint and a wrong release decision. Defines validation as objective evidence that a method is good enough for its intended use, for ISO/IEC 17025 laboratories. Introduces the Cebu food lab testing rice for cadmium, and a five-step view of a method's life.

    What you will be able to do

    • Explain what fit for purpose means and the three questions validation answers
    • Recognise that good-looking results without criteria or a statement are not yet a validation
    • Find which methods in your lab were developed or changed in-house

    Why it matters

    Shows why a lab must be able to show an assessor the evidence for any method on its scope, before the first result is reported.

    Practice: Practice: Why fit-for-purpose methods matter · 3 questions

  2. Verification or validation?7 min

    Sorts methods into the two routes the standard sets, verification for standard methods and validation for the rest, and the changes that restart validation.

    What this module covers

    Uses a family cake recipe to separate verification from validation, then gives the standard's terms. Names the four kinds of method that need validation: non-standard, lab-developed, standard methods used outside their scope and modified standard methods. Explains that a standard method is verified before introduction and again when revised, how to decide the influence of a change, and a worksheet applied to cases from several labs.

    What you will be able to do

    • Decide whether a method needs verification or validation, and explain why
    • Name the four kinds of method that require validation
    • Judge the influence of a change on a validated method and record the decision

    Why it matters

    Choosing the right route saves weeks of unnecessary experiments and puts effort where the risk really is.

    Practice: Practice: Verification or validation? · 3 questions

  3. Planning a validation8 min

    Teaches how to plan a validation from the customer's decision, with the lab's own criteria written and signed before any experiment is run.

    What this module covers

    Begins with an Ahmedabad lab that tested at full strength when the customer needed a low-level impurity. Lists the questions to ask the customer, then shows the Cebu lab's answers. Covers the standard's requirements for developing a method and the three-column plan of characteristic, experiment and criterion. Sets four rules: criteria before data, each tied to a need, validation as extensive as necessary, and plan approval.

    What you will be able to do

    • Turn a customer's decision, samples, accuracy and speed into validation requirements
    • Write a plan with a characteristic, an experiment and a criterion for each item
    • Trace each criterion back to a customer need and sign it before the data

    Why it matters

    A plan built from the decision keeps a validation short and relevant, and lets you say where each number came from.

    Practice: Practice: Planning a validation · 3 questions

Part 2The performance characteristicsApprox. 41 min
  1. Selectivity and specificity7 min

    Tests whether a method responds only to its target in the real samples it will meet, using blanks, spikes, look-alike substances and a second method.

    What this module covers

    Starts with a Melbourne pesticide lab whose method, checked only in clean solvent, reported a false positive in mango. Uses a busy café to explain selectivity and notes that some guides use the word specificity. Gives four checks: blanks, spikes, interfering substances and confirmation by a second method. Shows the Cebu rice results for both rice types, and common gaps such as clean standards only.

    What you will be able to do

    • Explain selectivity and how it differs from specificity
    • Plan blanks, spikes and interference checks for each sample type
    • Spot gaps such as clean standards only or look-alikes never named

    Why it matters

    A false positive can hold a whole shipment, and a missed interference can release a bad batch, so selectivity must be shown in the sample itself.

    Practice: Practice: Selectivity and specificity · 3 questions

  2. Working range and linearity7 min

    Sets the span of results a method can report with shown performance, and checks calibration linearity with back-calculated values and residuals.

    What this module covers

    Compares a kitchen scale and a truck weighbridge to show that every method has a range where its numbers can be trusted. Gives four steps: span, fit, check by back-calculation, and set the ends only with evidence. Shows the Cebu calibration check and why the correlation coefficient alone is not enough. Converts solution levels to rice levels, and covers samples above the top standard.

    What you will be able to do

    • Set a working range from the lowest to the highest level the evidence supports
    • Judge linearity by back-calculated standards and residuals, not one coefficient
    • Decide what to do with a result above the top standard

    Why it matters

    A result outside the range can look precise and still be wrong, so the scope, the method and the stated range must match.

    Practice: Practice: Working range and linearity · 3 questions

  3. Detection and quantification7 min

    Separates the limit of detection from the limit of quantification, and shows how to set both from your own low-level data against the customer's need.

    What this module covers

    Uses a whisper across a quiet room to show the difference between knowing something is there and knowing how much. Gives four steps to set the limits, repeating the whole method on low-level samples. Shows how the Cebu lab worked out both limits and compared them with its target and the buyers' limit. Covers reporting results near the limits, a Chicago soil lab case and common gaps.

    What you will be able to do

    • Explain the difference between detecting a substance and quantifying it
    • Set both limits from repeated whole-method low-level results
    • Check that your limits sit below the decision the customer must make

    Why it matters

    A not-detected result from a method that cannot see low enough can clear a site or shipment that should be stopped.

    Practice: Practice: Detection and quantification · 3 questions

  4. Trueness and bias7 min

    Checks whether a method gives the true value on average, using a reference material, spiked recovery and a comparison with another method.

    What this module covers

    Uses a bathroom scale that is steady but two kilos off to show that steady is not true. Defines bias and trueness, and gives the three ways to find bias described in the Eurachem guide. Shows the Cebu results from a rice reference material, a spike and a method comparison. Covers treating reference materials as equipment, a cement lab that checked its method against itself, and what to do when criteria are not met.

    What you will be able to do

    • Define bias and trueness and tell them apart from precision
    • Choose between a reference material, spikes and a second method to find bias
    • Judge a bias or recovery result against a criterion set beforehand

    Why it matters

    A method that is always a few per cent low can clear shipments that are over the limit, so the value you aim at must come from outside your own method.

    Practice: Practice: Trueness and bias · 3 questions

  5. Precision7 min

    Measures how much results scatter at three levels, repeatability, intermediate precision and reproducibility, under conditions that change as in routine work.

    What this module covers

    Uses a café chain's coffee at three levels to explain precision. Defines repeatability, intermediate precision within one lab and reproducibility across labs. Gives four steps to measure precision, varying what really changes in routine work. Shows the Cebu lab's repeatability and five-day results and what they teach. Covers a Johor Bahru milk powder case and gaps such as instrument repeats only.

    What you will be able to do

    • Distinguish repeatability, intermediate precision and reproducibility
    • Design a precision study that varies days, analysts and reagent batches
    • Judge relative standard deviations against criteria set before the work

    Why it matters

    If the real spread is bigger than you think, a result just under a limit may really be over it, so measure the precision customers actually get.

    Practice: Practice: Precision · 3 questions

  6. Robustness and carry-over7 min

    Covers robustness: which small changes in conditions move the results, how to control them in the method, and whether one sample leaves a trace in the next.

    What this module covers

    Uses cooking rice to explain a forgiving recipe with one sensitive step. Defines robustness, with the standard's examples of incubator temperature and a dispensed volume, and the Eurachem word ruggedness. Gives four steps to test it. Shows the Cebu study, where a cooler heater block gave low results and the temperature is now controlled. Also covers carry-over, a Pune incubator case and common gaps.

    What you will be able to do

    • List the steps of a method that could drift in routine work and vary each one
    • Write tighter limits for a sensitive step into the method
    • Test carry-over with a blank straight after the highest level

    Why it matters

    Finding the sensitive step before routine work does stops results from changing with the day, the analyst or the season.

    Practice: Practice: Robustness and carry-over · 3 questions

Part 3Verification, calibration, reporting and keeping validApprox. 48 min
  1. Techniques and uncertainty7 min

    Maps the six validation techniques the standard lists onto the worked case, and shows how validation data feed measurement uncertainty.

    What this module covers

    Starts with a Leeds lab whose in-house checks all shared one weak stock solution. Lists the six techniques: reference materials, a systematic look at every factor, varying controlled conditions, comparison with other validated methods, interlaboratory comparison and an evaluation of uncertainty. Gives three rules for choosing techniques, including one check from outside the lab's own materials. Explains uncertainty and which validation data feed it.

    What you will be able to do

    • Name the six validation techniques the standard lists
    • Choose independent techniques that can catch each other's errors
    • Identify which validation data feed a measurement uncertainty

    Why it matters

    Independent checks protect a lab from an error shared by every check, and good validation data supply most numbers the uncertainty needs.

    Practice: Practice: Techniques and uncertainty · 3 questions

  2. Verifying a standard method7 min

    Shows how a lab proves it can properly perform a published standard method, before the first customer result goes out.

    What this module covers

    Opens with an Abu Dhabi lab that started testing customer samples without any evidence it could achieve the method's performance. Explains that verification is done before introduction, with records kept, and repeated when the issuer revises the method. Gives four steps and the Abu Dhabi results. Covers deviations and their four conditions, a Bengaluru case where scope turned verification into validation, and common gaps.

    What you will be able to do

    • Verify a standard method against its published performance and the customer's need
    • Decide when a revised method needs checking again
    • State the four conditions for a documented deviation from a method

    Why it matters

    Results reported before verification have no evidence behind them, and the lab may have to withdraw them.

    Practice: Practice: Verifying a standard method · 3 questions

  3. Calibration labs7 min

    Applies verification and validation to calibration procedures, where the uncertainty at every point is usually the characteristic that matters most.

    What this module covers

    Explains that in a calibration lab the method is the calibration procedure, and the same rules apply. Gives four cases needing validation and four steps to validate a procedure. Follows a Chennai pressure gauge lab that compared results with another accredited lab within combined uncertainties and evaluated uncertainty at each point. Links to traceability and shows a Houston software change that forced certificates to be reissued.

    What you will be able to do

    • Decide when a calibration procedure needs validation
    • Validate a procedure by comparison with another lab and an uncertainty evaluation
    • Treat a software change as a change to the method

    Why it matters

    One unchecked procedure change can mean weeks of certificates reissued and customers asking why.

    Practice: Practice: Calibration labs · 3 questions

  4. Records and the report7 min

    Turns validation data into a signed report that ends with a clear statement of validity, and handles a change that comes later.

    What this module covers

    Lists the five things the standard asks a lab to keep from a validation. Shows the heart of the Cebu report, each characteristic with its criterion, result and yes or no, including the result that was first not met. Gives the statement of validity that closes the report. Covers technical records, what to repeat when the instrument changes, the report addendum, and common report gaps.

    What you will be able to do

    • List the five records a validation should keep
    • Write a statement of validity naming sample types, range, use and conditions
    • Decide what to repeat and record after an instrument change

    Why it matters

    A file of good data with no signed decision cannot be defended at an assessment or to a customer.

    Practice: Practice: Records and the report · 3 questions

  5. Keeping a method valid7 min

    Watches a validated method every day with control materials, replicates and comparisons, and acts when a chart or proficiency result gives a signal.

    What this module covers

    Uses a car's warning lights to explain daily monitoring after validation. Lists four ways suited to most testing labs, then shows the Cebu control chart with warning lines, action lines and a seven-in-a-row rule. Adds proficiency testing and other comparisons between labs. Covers what to do on a signal, a Kuala Lumpur case where a drifting chart preceded a failed proficiency result, and common gaps.

    What you will be able to do

    • Set up control chart rules for warning, action and drift
    • Explain why comparisons with other labs catch what a chart cannot
    • Respond to a signal by holding results, finding the cause and looking back

    Why it matters

    A method can drift for weeks while every result goes out with the lab's name on it, so monitoring keeps it as good as the day it was signed.

    Practice: Practice: Keeping a method valid · 3 questions

  6. Sector notes7 min

    Shows where validation pressure falls in food, water and environment, and pharmaceutical quality control labs, including the ICH guidelines.

    What this module covers

    Explains that the rules apply in every sector, but the pressure differs: sample variety in food labs, low levels and sample handling in water and environment labs, and regulators' guidance in pharmaceutical labs. Uses cases from Manila, Sydney and Hyderabad. Covers grouping foods, holding times, ICH Q2(R2) and Q14 with the analytical target profile, and points to ISO 15189 for medical laboratories.

    What you will be able to do

    • Identify the main validation risk for your sector
    • Justify and record a grouping of sample types
    • Explain how the ICH target profile fits the validation plan

    Why it matters

    Customers and regulators in each sector expect you to know its trap, and a method shown on one sample type is not shown on all.

    Practice: Practice: Sector notes · 3 questions

  7. Findings and your part7 min

    Brings the course together with the seven findings assessors raise most often about methods, and who does what in the lab.

    What this module covers

    Follows a Melbourne construction materials lab preparing for an assessment by checking four methods against seven findings. Lists them: no verification, no criteria, late criteria, characteristics that miss the need, unjudged changes, no link to quality control and no statement of validity. Sets out the roles of analysts, technical managers and quality managers, then the single thread from customer need to daily monitoring.

    What you will be able to do

    • Check a method against the seven most common assessment findings
    • Assign validation tasks to analysts, technical managers and quality managers
    • Explain a method's path from customer need to monitoring when asked

    Why it matters

    Most findings are easy to prevent, and walking your own methods before the assessor does saves time, money and scope.

    Practice: Practice: Findings and your part · 3 questions

Your certificates

Will my assessor, employer or accreditation body accept the certificate?

Included

A certificate you can verify, and share

Verifiable certificate with a QR code anyone can scan, plus a digital badge to add to your LinkedIn profile.

See how verification works →

You will be able to apply Method Validation and Verification (ISO/IEC 17025:2017) at work and show your competence with confidence at the accreditation assessment. Your certificate can be verified online in seconds, so assessors, employers and clients can confirm your training instantly.

How our courses are made and checked

Complete the course and its final exam and you receive a Sterling Academy Certificate of Completion, verifiable online by QR code, with a LinkedIn badge to share.

Pass mark
70%
Retakes
Retakes are unlimited and included in the course price: if you do not reach the pass mark, you can sit the final exam again as often as you need.
Prerequisites
None
Ask about course requirements

Who built this course

Prepared by the Sterling expert panel.

Sterling has 20+ years and 8,100+ client engagements in 60+ countries. The course is built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC, on the current edition of the standard. Online and self-paced, built the way we build our classroom training: in the same content and format as Sterling’s classroom training. Professionals from laboratories accredited by bodies such as NABL, UKAS, EIAC, IAS, UAF, NATA, IANZ and PAB have completed Sterling's training on this standard.

Prepared by the Sterling expert panel · Last updated 4 October 2026 · How our courses are made

Sterling Academy courses are built in the same content and format as Sterling's classroom training. Professionals from laboratories accredited by bodies such as NABL, UKAS, EIAC, IAS, UAF, NATA, IANZ and PAB have completed Sterling's training on this standard.

Standard and edition
ISO/IEC 17025:2017
Last updated
4 October 2026
Who it’s for
Analysts, calibration technicians, technical managers and quality managers in ISO/IEC 17025 laboratories
Learning format
Self-paced online training (video)
Video
16 modules · about 110 minutes
Total learning time
About 3.5 hours including practice questions and the final exam
Language
English, with captions
Support
Questions answered by a Sterling consultant
Final exam
Online, pass mark 70%
Access
12 months
On successful completion
Sterling Academy Certificate of Completion

Who it is for

Who should take Method Validation and Verification (ISO/IEC 17025:2017)?

Analysts, calibration technicians, technical managers and quality managers in ISO/IEC 17025 laboratories

Training a team? Every learner gets their own access and certificate, and the client administrator sees each person’s progress and result in one place.

Part of the ISO/IEC 17025:2017 learning path → Step 2

Part of the ISO 15189:2022 learning path → Step 2

Terms in this course: Method verification · Validation

About this course

Why does every reported result depend on a fit-for-purpose method?

A result is only as reliable as the method that produced it, and an accreditation assessor will ask how the laboratory knows its method works in its own hands, on its own samples. A published standard method may perform differently with a new instrument, a different matrix or a lower concentration than the one it was written for. A method developed in-house, or a standard method modified to save time, has no published evidence behind it at all. If the laboratory cannot show that performance was checked against the customer’s needs, every report issued with that method is open to challenge. The course explains how to build that evidence efficiently: defining what the result will be used for, setting acceptance criteria before collecting data and recording the study so that someone outside the laboratory can follow the reasoning.

When does a laboratory verify a method, and when must it validate one?

In broad terms, a laboratory verifies a standard method to show it can perform the method properly before use, and validates methods that are non-standard, developed by the laboratory or used outside their intended scope or modified. Verification confirms that the laboratory achieves the performance the method claims, usually through a focused set of experiments on precision, trueness and the working range. Validation goes further, establishing the performance characteristics from the beginning and judging them against the intended use. The course uses decision trees and examples to make the call clear: an unchanged pharmacopoeia method on a matching sample, a published method applied to a new matrix, an in-house chromatography method and a modified calibration procedure. Learners practise justifying each decision in writing, because assessors look for the reasoning as much as the data.

Which performance characteristics does a validation study evaluate?

A validation study evaluates the characteristics that matter for the intended use, typically selectivity, working range and linearity, limits of detection and quantification, trueness and bias, precision and robustness. Selectivity shows the method measures what it claims despite interferences. Linearity and range confirm that response and concentration relate predictably across the levels the customer needs. Detection and quantification limits show the lowest amounts that can be detected and reported with confidence. Trueness compares results with reference values, while precision covers repeatability and intermediate precision across days, analysts and instruments. Robustness tests whether small, deliberate changes, such as temperature or pH, affect results, and carry-over checks guard against contamination between samples. The course explains how to design each experiment, how many data points are sensible and how the results feed the uncertainty estimate.

What records and report does an assessor expect to see?

An assessor expects a validation plan written before the work, raw data that can be traced to instruments and analysts, the calculations, a comparison with the predefined criteria and a clear conclusion on fitness for purpose, approved by an authorised person. Common gaps include acceptance criteria chosen after the results were known, missing information on reagent lots or instrument settings, spreadsheets that were never checked, and reports that list statistics without saying whether the method is fit for use. The course provides a structure for the plan and report and works through a complete example. It also covers verification records for standard methods and the specific considerations for calibration laboratories, where the focus is on the calibration procedure, the reference standards used and the uncertainty achieved at each calibration point.

How does a laboratory keep a method valid once it is in routine use?

A method stays valid only if the laboratory keeps checking that its performance has not drifted, through quality control, proficiency testing and controlled change. Control samples and control charts show whether precision and bias remain within the validated limits. Proficiency testing and inter-laboratory comparisons compare results with other laboratories and reveal problems internal checks can miss. When anything significant changes, such as a new instrument, column, reagent supplier or software version, the laboratory decides whether partial revalidation is needed and records that decision. The course explains how to set triggers for each type of change, how to trend quality control data and how to respond when results move outside limits. A closing section summarises the assessment findings most often raised on methods and shows how each one could have been prevented.

Who should take this course, and how does it relate to other ISO/IEC 17025 training?

The course is designed for analysts, calibration technicians, technical managers and quality managers in testing and calibration laboratories working to ISO/IEC 17025:2017. Laboratories building or reviewing their whole management system should also take “ISO/IEC 17025:2017 Implementation Training”, and staff who audit the laboratory can add “ISO/IEC 17025:2017 Internal Auditor Training”. Because validation data feeds the uncertainty budget, “Measurement Uncertainty (ISO/IEC 17025:2017)” is a natural companion. Pharmaceutical quality control laboratories may also need “Pharmaceutical Microbiology for QC Laboratories Training” for microbiological methods. Sterling Academy courses are built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC, and this one includes sector notes so that food, environmental, pharmaceutical and calibration laboratories each see examples close to their own work.

Save when you learn more

One course, a bundle or a pass.

Course passes

Also in the All-Access Pass: all 210 courses except Lead Auditor courses for US$499, about the price of 5 courses.

Compare the passes

For teams

From US$69 per learner

Each learner gets their own access and certificate; you see progress in one place.

Price your team →

Save when you take more than one course

The discount is added automatically in your basket.

  • 15% off2 courses
  • 20% off3 courses
  • 25% off4 or more

What learners say

Rated by industry professionals like you

Every course is built by the experts behind 8,100+ client engagements in 60+ countries, so you learn what auditors and regulators actually expect. Here is what professionals said after finishing their course.

Informative

10/10 for Philippines Data Privacy Act and DPO Training

  • Built by the experts behind 8,100+ client engagements in 60+ countries
  • Certificate verifiable online
  • 12 months' access

10/10

“Informative”

Philippines Data Privacy Act and DPO Training

US$99list price US$149

Enrol now

10/10

“Engaging”

Supplier Evaluation & Second-Party Audits

US$99list price US$149

Enrol now

10/10

“Excellent”

Nonconformity Management

10/10

“Truly enjoyed”

Risk Management (ISO 31000:2018)

10/10

“Good course”

HIPAA Awareness

10/10

“Amazing course”

ISO/IEC 27001:2022 Awareness

10/10

“Very helpful”

ISO 9001:2026 Awareness

Better value

All-Access Pass

A pharma and life sciences professional from the USA started with one course, then upgraded to the All-Access Pass.

Every Sterling Academy course except Lead Auditor courses, for 12 months.

A selection of comments from learners who finished a course and answered our feedback request, shortened from their own words. Client names available on request.

Frequently asked questions

Questions about Method Validation and Verification (ISO/IEC 17025:2017)

About Method Validation and Verification (ISO/IEC 17025:2017), its certificate and enrolment.

Ask Sterling
Is Sterling Academy a good choice for ISO/IEC 17025 training?

Yes. Sterling Academy's ISO/IEC 17025 courses are built by the Sterling consulting group, which has taken organisations to accreditation and certification across 8,100+ client engagements in 60+ countries over 20+ years. They cover the awareness, implementation, internal auditor and specialist levels, always on the current edition, with practice questions that show the right answer. Each course ends with a final exam and a certificate that anyone can verify online, plus a LinkedIn badge, and client administrators can show an auditor exactly who has been trained. You will be able to apply Method Validation and Verification (ISO/IEC 17025:2017) at work and show your competence with confidence at the accreditation assessment. Sterling Academy courses are built in the same content and format as Sterling's classroom training. Professionals from laboratories accredited by bodies such as NABL, UKAS, EIAC, IAS, UAF, NATA, IANZ and PAB have completed Sterling's training on this standard.

Who is the Method Validation and Verification course for?

It is for analysts, calibration technicians, technical managers and quality managers in ISO/IEC 17025 laboratories. It suits laboratories preparing for ISO/IEC 17025 accreditation and accredited laboratories reviewing their methods. There are no prerequisites, and the course is taken online at the learner's own pace.

What does the Method Validation and Verification course cover?

It covers when to verify and when to validate, planning a study, the performance characteristics from selectivity to robustness, the validation report, and keeping a method valid in routine use. By the end, learners can decide whether a method needs verification or validation; plan a validation study with fitness-for-purpose criteria set in advance; evaluate selectivity, working range, linearity, limits of detection and quantification, trueness, precision and robustness; write a validation record and report that an assessor can follow; and keep a method valid through quality control, proficiency testing and change.

How long does the Method Validation and Verification course take?

It is a set of short video modules, each followed by practice questions, and a final exam. The course page shows the number of modules and the approximate video runtime; allow additional time for the practice questions and the exam. With 12 months of access, you can complete it in one sitting or spread it over several sessions.

Do learners receive a certificate?

Yes. Learners who reach the 70% pass mark in the final exam receive a Sterling Academy Certificate of Completion for Method Validation and Verification (ISO/IEC 17025:2017). Each certificate carries a unique number and a QR code, and anyone can verify it online using the certificate number and the holder's surname. It is a training certificate for the individual learner.

Is the course online and self-paced?

Yes. Method Validation and Verification (ISO/IEC 17025:2017) is a self-paced online course made of short video modules, in English with captions. You study at your own pace during 12 months of access, and practice questions after modules help you check your understanding before the final exam. If a point is unclear, questions are answered by a Sterling consultant.

Can we enrol a team, and how much does it cost?

Method Validation and Verification (ISO/IEC 17025:2017) has a list price of US$149 per learner, with a limited-time offer of US$99 per learner until 31 December 2026. Teams save 20% for 11 to 50 learners and 30% for 51 to 200; 201 or more learners are priced on request. Client administrators can track their team's progress. Prices are in US dollars, excluding taxes, and Sterling confirms final pricing and enrolment.

Your next step

Get ISO/IEC 17025 consulting from Sterling

Expert and experienced consultants, 8,100+ client engagements in 60+ countries, from gap assessment to a system ready for its accreditation assessment.

Talk to a Sterling consultant

Not sure which course?

Plan your next step
in learning.

Discuss your learning needs