Training requirements · US FDA QMSR (21 CFR Part 820)

Is competence and training mandatory under the FDA QMSR?

Yes. Since 2 February 2026, the FDA’s Quality Management System Regulation requires device manufacturers to meet ISO 13485:2016, incorporated by reference, including its competence requirement: people whose work affects quality must be competent through education, training, skills and experience, with records kept. ISO 13485 itself is not a law, and FDA does not require certification to it.

Key facts

In effect since
2 February 2026
Standard incorporated
ISO 13485:2016 (third edition), by reference
Applies to
Manufacturers of finished devices for human use made in, or imported or offered for import into, the US
Who must be competent
Anyone whose work affects product quality, including contractors and consultants
ISO 13485 certificate required
No; a certificate does not exempt a site from FDA inspection
Enforced by
US Food and Drug Administration

Checked against the official text on 16 November 2026

What changed when the QMSR came into effect?

On 2 February 2026 the FDA’s amended device cGMP rule took effect, retitled the Quality Management System Regulation. Instead of the agency’s own detailed text, the regulation now requires manufacturers to document a quality management system that complies with the applicable requirements of ISO 13485:2016, which it incorporates by reference, plus a short set of FDA-specific additions on matters such as unique device identification, complaint reporting and certain records.

The inspection approach changed on the same day. FDA states that it stopped using the Quality System Inspection Technique for device inspections and moved to an updated compliance programme for inspecting medical device manufacturers. Under the QMSR, FDA can also inspect management reviews, quality audits and supplier audit reports.

The old regulation had its own personnel section. Under the QMSR, FDA explains in the final rule that the competence requirement of ISO 13485 captures that intent, so training is now judged against the standard’s competence requirement as incorporated into US law.

Who must meet the QMSR competence requirement?

The QMSR applies to manufacturers that design, manufacture, package, label, store, install or service finished devices intended for human use, including contract sterilisers, relabellers, remanufacturers, repackers, specification developers and initial distributors of foreign manufacturers. It covers devices made in the United States and devices imported or offered for import. Manufacturers of components or parts are not covered, though FDA encourages them to consider the regulation.

Inside a covered manufacturer, the competence requirement reaches any individual doing work that affects quality. In the final rule FDA gives examples: internal and external personnel, full-time and part-time staff, contractors and consultants. A contract assembler’s operators, a consultant writing your risk file and a part-time inspector are all within it.

What must QMSR training and competence cover?

The requirement is framed as competence, not attendance. Each person must be competent for their work on the basis of appropriate education, training, skills and experience, and FDA states that these need to be carefully recorded. Training is therefore one route to competence among several, and the record must show how each person meets the competence set for their role. Typical content by role:

  • All quality-affecting staff: the quality policy, the procedures for their role, and how their work affects device safety and performance
  • Production and inspection staff: work instructions, process controls, nonconforming product, identification and traceability
  • Design and development teams: design controls, design reviews, verification and validation, and design transfer
  • Quality and regulatory staff: complaint handling, reporting to FDA, corrective and preventive action, internal audit and management review
  • Everyone involved in risk-related work: risk management, which ISO 13485 requires
  • Suppliers, contractors and consultants: the parts of your system that apply to the work they do for you

What evidence will an FDA investigator expect under the QMSR?

FDA investigators may review any records that form part of the manufacturer’s quality system, and FDA recommends that firms be prepared to discuss and provide them. For competence and training, keep:

  • A competence profile for each quality-affecting role, stating the education, training, skills and experience it needs
  • Individual records showing how each person, including contractors and consultants, meets that profile
  • Training records with content, version, date and outcome, retrained when procedures change
  • Evidence that training actually produced competence, such as assessments, observed work or supervisor sign-off
  • Management review and internal audit records that consider training and competence, since FDA can now inspect both
  • Supplier and contractor qualification records where external people do quality-affecting work

Is ISO 13485 certification required by FDA?

No. ISO 13485 is an international standard, not a law, and FDA has stated that it will not require or issue certificates of conformance to it. What the QMSR makes binding in the US is the content of the standard. A certificate also does not exempt a manufacturer from FDA inspection, because FDA inspections assess compliance with FDA regulations and are scheduled based on risk.

Manufacturers that also hold ISO 13485 certification, for other markets or for customers, face the same competence requirement in their certification audits. A certification body, not Sterling, issues that certificate. One well-kept competence and training system can serve the FDA investigator and the certification auditor.

How do you get a training system ready for the QMSR?

Manufacturers moving from the old regulation often have training procedures but thin competence evidence. These steps close that gap.

  1. Define competence by roleFor every quality-affecting role, state the education, training, skills and experience required.
  2. Map people to rolesInclude contractors, consultants, part-time staff and external personnel doing quality-affecting work.
  3. Close the gapsPlan training or other actions where a person does not yet meet the role’s competence, and record the result.
  4. Check that it workedConfirm competence after training through assessment, observation or supervised work, and record it.
  5. Review in the systemFeed training and competence into internal audits and management review, both of which FDA can now inspect.

What does good QMSR training look like for each role?

Competence must fit the work each person does, so a single course for everyone rarely meets the requirement. Plan depth by role.

  • Senior management: the quality policy and objectives, management review and their responsibility for the system FDA can now inspect
  • Design engineers and software developers: design controls, risk management and the records the design file needs
  • Production staff and inspectors: work instructions, process controls, nonconforming product and record keeping at the point of work
  • Complaint handlers and regulatory staff: complaint evaluation, reporting to FDA and advisory notices
  • Internal auditors: auditing the system against ISO 13485 and the QMSR additions, and reporting findings that management review will use
  • Purchasing and supplier quality staff: supplier evaluation and control, and the records FDA can review

Which QMSR competence gaps should you check for?

The move from the old regulation exposes some predictable gaps. Check these against your current files.

  • Training records exist, but no competence requirement is defined for the role, so there is nothing to measure them against
  • Contractors, consultants and part-time staff doing quality-affecting work have no competence records
  • Education, skills and experience are not recorded alongside training
  • Procedures still refer to the old regulation’s personnel provisions instead of the QMSR and ISO 13485
  • Management review and internal audits do not look at competence, although FDA can now inspect both

How does Sterling Academy support QMSR training?

Sterling Academy offers a dedicated US FDA QMSR course alongside ISO 13485:2016 awareness, implementation and internal auditor training, design controls and medical device risk management. The courses are built by industry experts, domain specialist trainers and globally renowned auditors with 30+ years in ISO and GRC, in the same content and format as Sterling’s classroom training, whose certificates are trusted and accepted by all major certification bodies. They are online and self-paced, which suits design, production and quality teams on different shifts and sites.

Each learner completes an assessment designed on the principles of ISO/IEC 17024:2026, the kind of evidence that helps show training produced competence, and receives a verifiable certificate with a QR code that an investigator or auditor can check. The internal auditor course prepares staff for your own internal audits; it does not qualify anyone to audit for a certification body.

Frequently asked questions

Questions about US FDA QMSR (21 CFR Part 820) training

Ask a Sterling consultant

When did the FDA QMSR take effect?

On 2 February 2026, two years after the final rule was published. FDA began enforcing the QMSR requirements from that date.

Does the QMSR still have a separate personnel training section?

No. FDA considers that the competence requirement of ISO 13485, incorporated by reference, captures the intent of the former provisions. Competence is now judged against that requirement.

Do contractors and consultants need to be competent under the QMSR?

Yes. FDA gives internal and external personnel, full-time and part-time staff, contractors and consultants as examples of individuals whose work affects quality and who must be competent.

Does an ISO 13485 certificate satisfy FDA?

No. FDA does not require or issue ISO 13485 certificates, and a certificate does not exempt a manufacturer from FDA inspection.

Can FDA now see our internal audit and management review records?

Yes. FDA states that the QMSR gives it authority to inspect management review, quality audits and supplier audit reports.

Does the QMSR set a training frequency?

No. The test is competence for the work each person does, not a calendar. Retrain when procedures, products or roles change, and when evidence such as nonconformities or audit findings shows that competence has slipped, and keep the record each time.

Does the QMSR apply to component suppliers?

Manufacturers of components or parts of finished devices are not subject to the regulation, though FDA encourages them to consider it. Your own supplier controls will still reach them.

Did the QMSR change which records FDA can see?

Yes. FDA states that the QMSR gives it authority to inspect management review, quality audits and supplier audit reports, so training and competence discussed there is visible to an investigator.

Training your team?

Plan the training
with a Sterling consultant.

Discuss your training needs